Purpose: To review the existing literature to (1) determine the diagnostic efficacy of artificial intelligence (AI) models for detecting scaphoid and distal radius fractures and (2) compare the efficacy to human clinical experts.

Methods: PubMed, OVID/Medline, and Cochrane libraries were queried for studies investigating the development, validation, and analysis of AI for the detection of scaphoid or distal radius fractures. Data regarding study design, AI model development and architecture, prediction accuracy/area under the receiver operator characteristic curve (AUROC), and imaging modalities were recorded.

Results: A total of 21 studies were identified, of which 12 (57.1%) used AI to detect fractures of the distal radius, and nine (42.9%) used AI to detect fractures of the scaphoid. AI models demonstrated good diagnostic performance on average, with AUROC values ranging from 0.77 to 0.96 for scaphoid fractures and from 0.90 to 0.99 for distal radius fractures. Accuracy of AI models ranged between 72.0% to 90.3% and 89.0% to 98.0% for scaphoid and distal radius fractures, respectively. When compared to clinical experts, 13 of 14 (92.9%) studies reported that AI models demonstrated comparable or better performance. The type of fracture influenced model performance, with worse overall performance on occult scaphoid fractures; however, models trained specifically on occult fractures demonstrated substantially improved performance when compared to humans.

Conclusions: AI models demonstrated excellent performance for detecting scaphoid and distal radius fractures, with the majority demonstrating comparable or better performance compared with human experts. Worse performance was demonstrated on occult fractures. However, when trained specifically on difficult fracture patterns, AI models demonstrated improved performance.

Clinical Relevance: AI models can help detect commonly missed occult fractures while enhancing workflow efficiency for distal radius and scaphoid fracture diagnoses. As performance varies based on fracture type, future studies focused on wrist fracture detection should clearly define whether the goal is to (1) identify difficult-to-detect fractures or (2) improve workflow efficiency by assisting in routine tasks.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhsa.2024.01.020DOI Listing

Publication Analysis

Top Keywords

distal radius
32
radius fractures
24
scaphoid distal
20
models demonstrated
16
fractures
14
occult fractures
12
scaphoid
9
performance
9
diagnostic performance
8
artificial intelligence
8

Similar Publications

We report a series of 12 patients who developed early distal radioulnar joint subluxation after a distal radial fracture, not present on the initial radiographs. Early identification and management of this condition can give good clinical results. IV.

View Article and Find Full Text PDF

Treatment of anterior rim fractures of the distal radius with an anterior rim plate: A retrospective study.

J Hand Surg Eur Vol

January 2025

Department of Orthopedics, E-Da Hospital, I-Shou University/School of Medicine, College of Medicine, I-Shou University, Kaohsiung, Taiwan.

Treatment of distal radial fractures that include small anterior rim fragments can be difficult. We retrospectively reviewed 19 patients in whom an anterior rim plate with locking screws was used. After a median follow-up of 18 months (range 6-32; interquartile range (IQR) 14, 26), the median wrist flexion and extension arc was 70° (range 50-80; IQR 60, 70), the median grip strength was 80% of the contralateral side (range 52-104; IQR 77, 88), the median visual analogue scale score for pain was 0 (range 0-5; IQR 0, 1), the median disabilities of the arm, shoulder and hand score was 2 (range 0-59; IQR 0, 11) and the median modified Mayo wrist score was 80 (range 35-100; IQR 75, 85).

View Article and Find Full Text PDF

The main objectives of this work are to validate a 1D-0D unsteady solver with a distributed stenosis model for the patient-specific estimation of resting haemodynamic indices and to assess the sensitivity of instantaneous wave-free ratio (iFR) predictions to uncertainties in input parameters. We considered 52 patients with stable coronary artery disease, for which 81 invasive iFR measurements were available. We validated the performance of our solver compared to 3D steady-state and transient results and invasive measurements.

View Article and Find Full Text PDF

Background: Unstable diametaphyseal radius fractures (DMRFs) can be prone to complications, and treatment strategies are heterogeneous. Studies are difficult to interpret as definitions of the diametaphyseal junction zone (DMJZ) are impractical for clinical use, imprecise, or prone to error.

Methods: We introduce the forearm fracture index (FFI) to define DMRFs in radiographs and ultrasound.

View Article and Find Full Text PDF

Background: Early-term complications may not predict long-term success after adult cervical deformity (ACD) correction.

Objective: Evaluate whether optimal realignment results in similar rates of perioperative complications but achieves longer-term cost-utility.

Study Design: Retrospective cohort study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!