AI Article Synopsis

  • - A 16-year-old male experienced cardiogenic shock caused by malfunction of his On-X mitral valve prosthesis, which was linked to a leaflet detaching and traveling through an aortic mechanical valve.
  • - He had to have an emergency surgery to replace the malfunctioning mitral valve, followed by another procedure to remove the dislodged leaflet a few days later.
  • - After these surgical interventions, the patient made a full recovery.

Article Abstract

We report a case of a 16-year-old man in cardiogenic shock secondary to On-X mitral prosthesis dysfunction due to leaflet embolization through aortic mechanical prosthesis. He underwent an emergency redo mitral valve replacement and, a few days later, leaflet removal by open aortic surgery with full recovery.