Introduction: Mitral valve stenosis (MS) can be concomitantly present in patients undergoing Transcatheter Aortic Valve Implantation (TAVI). Some studies have reported up to one-fifth of patients who underwent TAVI also have MS. The relationship between mitral stenosis and TAVI has led to concerns regarding increased adverse cardiac outcomes during and after the procedure.
Methods: The Nationwide Readmission Database (NRD 2016-2019) was utilized to identify TAVI patients with MS with ICD-10-CM codes. The primary outcome was a 30-day readmission rate. Secondary outcomes included predictors of all-cause readmissions, length of stay, and total hospitalization cost. We assessed readmission frequency with a national sample weighed at 30 days following the index TAVI procedure. Unadjusted and adjusted odds ratios were analyzed for in-hospital outcomes using univariate and multivariate logistic regression for study cohorts.
Results: A total of 217,147 patients underwent TAVI procedures during the queried time period of the study. Of these patients, 2140 (0.98 %) had MS. The overall 30-day all-cause readmission rate for the study cohort was 12.4 %. TAVI patients with MS had higher rates of 30-day readmissions (15.8 % vs 12.3 %, aOR 1.22, CI: 1.03-1.45, P < 0.01). Additionally, TAVI patients with MS had longer lengths of hospital stay during index admissions (5.7 vs. 4.3 days), along with higher total hospitalization costs ($55,157 vs. $50,239). In contrast, in-hospital mortality during index TAVI admission did not differ significantly between the two groups, although there was a trend toward higher mortality in the MS group (2.1 % vs. 1.5 %). Among the TAVI MS cohort, patients admitted on weekends (aOR: 1.11, 95 % CI: 1.02-1.22, P = 0.01), admitted to non-metropolitan hospitals (aOR: 1.29, 95 % CI: 1.11-1.66, P = 0.04) and presence of co-morbidities such as atrial fibrillation (AF)/flutter (aOR: 1.24, 95 % CI: 1.16-1.32, P < 0.01), chronic obstructive pulmonary disease (COPD) (aOR: 1.16, 95 % CI: 1.11-1.22, P < 0.01), prior stroke (aOR: 1.09, 95 % CI: 1.03-1.14, P < 0.01), chronic kidney disease (CKD) ≥3 (aOR: 1.16, 95 % CI: 1.11-1.22, P < 0.01), end-stage renal disease (ESRD) (aOR: 1.75, 95 % CI: 1.61-1.90, P < 0.01), and anemia (aOR: 1.23, 95 % CI: 1.18-1.28, P < 0.01) were associated with increased odds of readmission.
Conclusion: Concomitant MS in patients undergoing TAVI is associated with higher readmission rates and total hospital costs. This can contribute significantly to healthcare-related burdens. Further studies are required to evaluate in-hospital outcomes and predictors of readmission in patients undergoing TAVI with the presence of concomitant MS.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.carrev.2024.03.012 | DOI Listing |
Eur Heart J Case Rep
January 2025
The Second Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama, Toyama 930-0194, Japan.
Background: Self-expanding valves used in transcatheter aortic valve implantation (TAVI) are designed to allow recapture and repositioning, facilitating optimal placement and mitigating conduction disturbances and paravalvular leakage. Here, we present a rare case in which the Navitor (Abbott Structural Heart, Santa Clara, CA, USA) could not be recaptured.
Case Summary: An 81-year-old Japanese woman with very severe aortic stenosis and a massively calcified nodule at the non-coronary cusp (NCC) underwent TAVI with a 25 mm Navitor valve.
Eur Heart J Case Rep
January 2025
Tehran Heart Center, Cardiovascular Diseases Research Institute, Tehran University of Medical Sciences, North Kargar Ave, Tehran 1411713138, Iran.
Background: Since the transcatheter valve-in-valve (ViV) procedure was introduced in 2007, a few cases of infective endocarditis (IE) following the ViV procedure have been reported, which can be predisposed by older age, pre-existing medical conditions, and procedural techniques. Paravalvular abscesses constitute a rare complication of IE, resulting from extending IE beyond the valve annulus, less commonly caused by species. This complication is more common in prosthetic valves, particularly bioprosthetic valves.
View Article and Find Full Text PDFCJC Open
January 2025
Department of Cardiology, Royal North Shore Hospital, Sydney, Australia.
CJC Open
January 2025
Interventional Cardiology Service, Centro Medico Nacional 20 de Noviembre, Mexico City, Mexico.
Trauma Case Rep
February 2025
Department of Emergency and Critical Care Medicine, Hyogo Emergency Medical Center, 1-3-1 Wakinohamakaigandori, Chuo-ku, Kobe, Hyogo 651-0073, Japan.
Background: Hybrid emergency rooms (ERs) allow computed tomography (CT) scanning, interventional radiology, and surgery all in the same suite. Severe trauma patients with blunt thoracic aortic injury (BTAI) require rapid diagnosis and treatment. Hybrid ERs allow the potential for clinicians to implement multiple therapeutic procedures, including thoracic endovascular aortic repair (TEVAR), for these types of conditions without the need to transport the patients.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!