A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ex-vivo systems for neuromodulation: A comparison of ex-vivo and in-vivo large animal nerve electrophysiology. | LitMetric

Ex-vivo systems for neuromodulation: A comparison of ex-vivo and in-vivo large animal nerve electrophysiology.

J Neurosci Methods

Centre for Accountable, Responsible, and Transparent AI (ART-AI), Department of Computer Science, University of Bath, Claverton Down, Bath, BA2 7AY, United Kingdom; The Bath Institute for the Augmented Human, University of Bath, Claverton Down, Bath, BA2 7AY, United Kingdom. Electronic address:

Published: June 2024

Background: Little research exists on extending ex-vivo systems to large animal nerves, and to the best of our knowledge, there has yet to be a study comparing these against in-vivo data. This paper details the first ex-vivo system for large animal peripheral nerves to be compared with in-vivo results.

New Method: Detailed ex-vivo and in-vivo closed-loop neuromodulation experiments were conducted on pig ulnar nerves. Temperatures from 20 °C to 37 °C were evaluated for the ex-vivo system. The data were analysed in the time and velocity domains, and a regression analysis established how evoked compound action potential amplitude and modal conduction velocity (CV) varied with temperature and time after explantation.

Main Results: Pig ulnar nerves were sustained ex-vivo up to 5 h post-explantation. CV distributions of ex-vivo and in-vivo data were compared, showing closer correspondence at 37 °C. Regression analysis results also demonstrated that modal CV and time since explantation were negatively correlated, whereas modal CV and temperature were positively correlated.

Comparison With Existing Methods: Previous ex-vivo systems were primarily aimed at small animal nerves, and we are not aware of an ex-vivo system to be directly compared with in-vivo data. This new approach provides a route to understand how ex-vivo systems for large animal nerves can be developed and compared with in-vivo data.

Conclusion: The proposed ex-vivo system results were compared with those seen in-vivo, providing new insights into large animal nerve activity post-explantation. Such a system is crucial for complementing in-vivo experiments, maximising collected experimental data, and accelerating neural interface development.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jneumeth.2024.110116DOI Listing

Publication Analysis

Top Keywords

large animal
20
ex-vivo systems
16
ex-vivo system
16
compared in-vivo
16
ex-vivo
12
ex-vivo in-vivo
12
animal nerves
12
in-vivo data
12
in-vivo
9
animal nerve
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!