Isolated scan unit and scanning tunneling microscope for stable imaging in ultra-high magnetic fields.

Ultramicroscopy

Anhui Key Laboratory of Low-Energy Quantum Materials and Devices, High Magnetic Field Laboratory, HFIPS, Chinese Academy of Sciences, Hefei 230031, Anhui, China; The High Magnetic Field Laboratory of Anhui Province, Hefei 230031, Anhui, China; Hefei National Research Center for Physical Sciences at the Microscale, University of Science and Technology of China, Hefei 230026, Anhui, China; Anhui Laboratory of Advanced Photon Science and Technology, University of Science and Technology of China, Hefei Anhui 230026, China; Hefei Science Center, Chinese Academy of Sciences, Hefei 230031, China. Electronic address:

Published: July 2024

The high resolution of a scanning tunneling microscope (STM) relies on the stability of its scan unit. In this study, we present an isolated scan unit featuring non-magnetic design and ultra-high stability, as well as bidirectional movement capability. Different types of piezoelectric motors can be incorporated into the scan unit to create a highly stable STM. The standalone structure of scan unit ensures a stable atomic imaging process by decreasing noise generated by motor. The non-magnetic design makes the scan unit work stable in high magnetic field conditions. Moreover, we have successfully constructed a novel STM based on the isolated scan unit, in which two inertial piezoelectric motors act as the coarse approach actuators. The exceptional performance of homebuilt STM is proved by the high-resolution atomic images and dI/dV spectrums on NbSe surface at varying temperatures, as well as the raw-data images of graphite obtained at ultra-high magnetic fields of 23 T. According to the literature research, no STM has previously reported the atomic image at extreme conditions of 2 K low temperature and 23 T ultra-high magnetic field. Additionally, we present the ultra-low drift rates between the tip and sample at varying temperatures, as well as when raising the magnetic fields from 0 T to 23 T, indicating the ultra-high stability of the STM in high magnetic field conditions. The outstanding performance of our stable STM hold great potential for investigating the materials in ultra-high magnetic fields.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2024.113960DOI Listing

Publication Analysis

Top Keywords

scan unit
28
ultra-high magnetic
16
magnetic fields
16
isolated scan
12
magnetic field
12
scanning tunneling
8
tunneling microscope
8
non-magnetic design
8
ultra-high stability
8
piezoelectric motors
8

Similar Publications

Comparison between ZenoTOF 7600 system and QTOF for plant metabolome: an example of metabolomics applied to coffee leaves.

Metabolomics

January 2025

Bioanalysis and Drug Discovery, Faculty of Pharmacy, RD3 Unit of Pharmacognosy, Université Libre de Bruxelles, Bd du Triomphe, Campus Plaine, CP 205/09, 1050, Brussels, Belgium.

Introduction: ZenoTOF is new class of high-resolution mass spectrometer that combines resolution and sensitivity. This mass spectrometer is well designed to perform metabolomics.

Methods: In this context, we compared the performance of ZenoTOF 7600 system (Sciex) with QTOF6520 (Agilent Technologies) through the leaf metabolome analysis of two Coffea species, namely C.

View Article and Find Full Text PDF

A 56-year-old male smoker presented to the Emergency Department with a painful mass in the left ischiorectal fossa, which had been present for 2 months without any other symptoms. On examination, a hard, violet-colored mass was observed, with an ulcerated central area. Blood tests were normal, and the abdominal-pelvic CT scan showed multiple hypervascular intra-abdominal masses and soft tissue lesions.

View Article and Find Full Text PDF

Objectives Of The Study: (1) To evaluate the effect of platelet-rich fibrin (PRF) with bone marrow aspirate on regenerative capacity in patients undergoing iliac bone grafting for secondary alveolar bone grafting. (2) and to compare it with group 2 where only bone marrow aspirate was used along with iliac bone graft in secondary alveolar bone grafting.

Materials And Methods: A prospective study on patients with cleft alveolus, requiring bone grafting and reporting to our unit from October 2018 to October 2020 was included in this study.

View Article and Find Full Text PDF

Jansen metaphyseal chondrodysplasia (JMC) is an ultra-rare disorder caused by constitutive activation of parathyroid hormone type 1 receptor (PTH1R). We sought to characterize the craniofacial phenotype of patients with the disease. Six patients with genetically confirmed JMC underwent comprehensive craniofacial phenotyping revealing a distinct facial appearance that prompted a cephalometric analysis demonstrating a pattern of mandibular retrognathia.

View Article and Find Full Text PDF

Objective: The objective of this scoping review is to develop a list of items for potential inclusion in the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) reporting guidelines for network meta-analysis (NMA), scoping reviews (ScRs), and rapid reviews (RRs).

Introduction: The PRISMA extensions for NMA and ScRs were published in 2015 and 2018. However, since then, their methodologies and innovations, including automation, have evolved.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!