A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

MXene/Silk Fibroin Strengthened PVA-Based Eutectogel with Excellent Self-Healing Ability and Environmental Adaptability: Design, Synthesis, and Sensing Application. | LitMetric

A superelastic self-healing eutectogel was designed and prepared using poly (vinyl alcohol) (PVA) as the bulk skeleton material, while silk fibroin (SF) and two-dimensional (2D) MXene (TiCT) as reinforcing fillers. In brief, the eutectogel possesses a high tensile strength of 7.63 MPa, and its elongation at break reached 1115.2%, higher than most reported polymers (<1000%). In addition, the eutectogel-assembled sensor has a high ionic conductivity of 0.61 S/m and a high strain sensitivity of 5.17 kPa. Moreover, eutectogel shows excellent self-healing ability and can achieve self-healing quickly within 10 min, while its tensile strength and elongation at break can be restored to 84.7% and 97.4% of the initial levels. Besides, a stable electrical signal can be transmitted after 200 cycles at 30% strain. Finally, the eutectogel can withstand various environmental conditions, such as atmospheric or even vacuum evaporation and low-temperature freezing, while maintaining good mechanical and sensing performances. The assembled flexible sensors based on the eutectogel demonstrate their significant application prospects in wearable devices, especially human physiological monitoring.

Download full-text PDF

Source
http://dx.doi.org/10.1002/asia.202400055DOI Listing

Publication Analysis

Top Keywords

mxene/silk fibroin
4
fibroin strengthened
4
strengthened pva-based
4
pva-based eutectogel
4
eutectogel excellent
4
excellent self-healing
4
self-healing ability
4
ability environmental
4
environmental adaptability
4
adaptability design
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!