Background: Computed tomography (CT) chest scans have become commonly used in clinical diagnosis. Image quality assessment (IQA) for CT images plays an important role in CT examination. It is worth noting that IQA is still a manual and subjective process, and even experienced radiologists make mistakes due to human limitations (fatigue, perceptual biases, and cognitive biases). There are also kinds of biases because of poor consensus among radiologists. Excellent IQA methods can reliably give an objective evaluation result and also reduce the workload of radiologists. This study proposes a deep learning (DL)-based automatic IQA method, to assess whether the image quality of respiratory phase on CT chest images are optimal or not, so that the CT chest images can be used in the patient's physical condition assessment.

Methods: This retrospective study analysed 212 patients' chest CT images, with 188 patients allocated to a training set (150 patients), validation set (18 patients), and a test set (20 patients). The remaining 24 patients were used for the observer study. Data augmentation methods were applied to address the problem of insufficient data. The DL-based IQA method combines image selection, tracheal carina segmentation, and bronchial beam detection. To automatically select the CT image containing the tracheal carina, an image selection model was employed. Afterward, the area-based approach and score-based approach were proposed and used to further optimize the tracheal carina segmentation and bronchial beam detection results, respectively. Finally, the score about the image quality of the patient's respiratory phase images given by the DL-based automatic IQA method was compared with the mean opinion score (MOS) given in the observer study, in which four blinded experienced radiologists took part.

Results: The DL-based automatic IQA method achieved good performance in assessing the image quality of the respiratory phase images. For the CT sequence of the same patient, the DL-based IQA method had an accuracy of 92% in the assessment score, while the radiologists had an accuracy of 88%. The Kappa value of the assessment score between the DL-based IQA method and radiologists was 0.75, with a sensitivity of 85%, specificity of 91%, positive predictive value (PPV) of 92%, negative predictive value (NPV) of 93%, and accuracy of 88%.

Conclusions: This study develops and validates a DL-based automatic IQA method for the respiratory phase on CT chest images. The performance of this method surpassed that of the experienced radiologists on the independent test set used in this study. In clinical practice, it is possible to reduce the workload of radiologists and minimize errors caused by human limitations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10963826PMC
http://dx.doi.org/10.21037/qims-23-1273DOI Listing

Publication Analysis

Top Keywords

iqa method
28
image quality
20
respiratory phase
20
chest images
20
dl-based automatic
16
automatic iqa
16
experienced radiologists
12
dl-based iqa
12
tracheal carina
12
iqa
10

Similar Publications

Pentafluoroorthotellurate Uncovered: Theoretical Perspectives on an Extremely Electronegative Group.

Inorg Chem

January 2025

Departamento de Química Física and Instituto de Biocomputación y Física de Sistemas Complejos (BIFI), Universidad de Zaragoza, Zaragoza 50009, Spain.

Article Synopsis
  • The pentafluoroorthotellurate group (-OTeF, teflate) is a potent electron-withdrawing substitute for fluoride, known for its stability and size, which helps avoid bridging ligand behavior.
  • This study employs advanced Quantum Chemical Topology methods to analyze the electronic structure and bonding of the teflate group, comparing its electronegativity with halogens and investigating the interactions in various XOTeF systems.
  • Findings reveal that while teflate exhibits strong electron-withdrawing abilities akin to fluorine, its bonding is predominantly ionic and shares similar electronegativity traits with other O-donor groups.
View Article and Find Full Text PDF

Open ultrawidefield fundus image dataset with disease diagnosis and clinical image quality assessment.

Sci Data

November 2024

Department of Ophthalmology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou, Zhejiang, China.

Ultrawidefield fundus (UWF) images have a wide imaging range (200° of the retinal region), which offers the opportunity to show more information for ophthalmic diseases. Image quality assessment (IQA) is a prerequisite for applying UWF and is crucial for developing artificial intelligence-driven diagnosis and screening systems. Most image quality systems have been applied to the assessments of natural images, but whether these systems are suitable for evaluating the UWF image quality remains debatable.

View Article and Find Full Text PDF

Introduction: We propose a fully automated framework to conduct a region-wise image quality assessment (IQA) on whole-body 18 F-FDG PET scans. This framework (1) can be valuable in daily clinical image acquisition procedures to instantly recognize low-quality scans for potential rescanning and/or image reconstruction, and (2) can make a significant impact in dataset collection for the development of artificial intelligence-driven 18 F-FDG PET analysis models by rejecting low-quality images and those presenting with artifacts, toward building clean datasets.

Patients And Methods: Two experienced nuclear medicine physicians separately evaluated the quality of 174 18 F-FDG PET images from 87 patients, for each body region, based on a 5-point Likert scale.

View Article and Find Full Text PDF

In recent years, the High-Dynamic-Range (HDR) image has gained widespread popularity across various domains, such as the security, multimedia, and biomedical fields, owing to its ability to deliver an authentic visual experience. However, the extensive dynamic range and rich detail in HDR images present challenges in assessing their quality. Therefore, current efforts involve constructing subjective databases and proposing objective quality assessment metrics to achieve an efficient HDR Image Quality Assessment (IQA).

View Article and Find Full Text PDF
Article Synopsis
  • * To improve Image Quality Assessment (IQA) for distorted images, a new method using the Swin Transformer (ST) with a Global Self-Attention Block (GSAB) is proposed, allowing the model to effectively focus on spatial and channel information.
  • * Experiments conducted on multiple synthetic and authentic datasets demonstrate that this new method outperforms existing techniques and shows strong generalization ability, providing promising results in predicting image quality scores.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!