A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

From Movements to Metrics: Evaluating Explainable AI Methods in Skeleton-Based Human Activity Recognition. | LitMetric

From Movements to Metrics: Evaluating Explainable AI Methods in Skeleton-Based Human Activity Recognition.

Sensors (Basel)

Department of Neuromedicine and Movement Science, Faculty of Medicine and Health Sciences, Norwegian University of Science and Technology, 7034 Trondheim, Norway.

Published: March 2024

The advancement of deep learning in human activity recognition (HAR) using 3D skeleton data is critical for applications in healthcare, security, sports, and human-computer interaction. This paper tackles a well-known gap in the field, which is the lack of testing in the applicability and reliability of XAI evaluation metrics in the skeleton-based HAR domain. We have tested established XAI metrics, namely faithfulness and stability on Class Activation Mapping (CAM) and Gradient-weighted Class Activation Mapping (Grad-CAM) to address this problem. This study introduces a perturbation method that produces variations within the error tolerance of motion sensor tracking, ensuring the resultant skeletal data points remain within the plausible output range of human movement as captured by the tracking device. We used the NTU RGB+D 60 dataset and the EfficientGCN architecture for HAR model training and testing. The evaluation involved systematically perturbing the 3D skeleton data by applying controlled displacements at different magnitudes to assess the impact on XAI metric performance across multiple action classes. Our findings reveal that faithfulness may not consistently serve as a reliable metric across all classes for the EfficientGCN model, indicating its limited applicability in certain contexts. In contrast, stability proves to be a more robust metric, showing dependability across different perturbation magnitudes. Additionally, CAM and Grad-CAM yielded almost identical explanations, leading to closely similar metric outcomes. This suggests a need for the exploration of additional metrics and the application of more diverse XAI methods to broaden the understanding and effectiveness of XAI in skeleton-based HAR.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10975804PMC
http://dx.doi.org/10.3390/s24061940DOI Listing

Publication Analysis

Top Keywords

human activity
8
activity recognition
8
skeleton data
8
skeleton-based har
8
class activation
8
activation mapping
8
xai
5
movements metrics
4
metrics evaluating
4
evaluating explainable
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!