A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Skeletal Muscle Echo Intensity Values Differ Significantly across Ultrasound Parameter Settings. | LitMetric

Skeletal Muscle Echo Intensity Values Differ Significantly across Ultrasound Parameter Settings.

Life (Basel)

Postgraduate Program in Nutrition and Food, Federal Univeristy of Pelotas, Rua Gomes Carneiro, 01-Centro, Pelotas 96010-610, Brazil.

Published: February 2024

Echo intensity determined by muscle ultrasound has been proposed as an efficient method for the assessment of muscle quality. The influence of changing ultrasound parameter settings on echo intensity values was assessed using a standardized approach. In this repeated measures cross-sectional study, sixteen repeated scans of rectus femoris, gracilis, and rectus abdominis were taken in 21 middle-aged persons with a portable Mindray M7 premium ultrasound machine equipped with a linear 5.0-10.0 MHz transducer. The settings of three parameters were fixed: gain, depth, and frequency. The settings of the following adjustable parameters were changed over their entire range: dynamic range, gray map, line density, persistence, and IClear. Repeated measures analyses were performed to evaluate the effect of changing the settings on echo intensity values. In all three muscles, dynamic range, gray map, and IClear correlated significantly (r-values ranging between -0.86 and 0.45) with echo intensity. In all three muscles, the echo intensity values differed significantly across the dynamic range ( < 0.013), gray map ( < 0.003), and IClear ( < 0.003). In middle-aged subjects, echo intensity values of lower limb and trunk muscles are significantly related to ultrasound parameters and significantly differ across their respective setting range. For the assessment of muscle quality through ultrasound, it is suggested to fix parameter settings within their midrange in order to minimize the effect of setting-dependent factors on EI values.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10971078PMC
http://dx.doi.org/10.3390/life14030291DOI Listing

Publication Analysis

Top Keywords

echo intensity
28
intensity values
20
parameter settings
12
settings echo
12
dynamic range
12
gray map
12
ultrasound parameter
8
assessment muscle
8
muscle quality
8
repeated measures
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!