Introduction: Patient satisfaction is an important outcome of total knee arthroplasty (TKA). However, we cannot predict how and why patients are satisfied or dissatisfied with TKA. The hypothesis of this study was that patient-reported outcomes (PROs) correlate with in vivo kinematics after TKA.

Materials And Methods: One hundred knees were analyzed after TKA. The in vivo kinematics of deep knee bending motion were estimated from single-plane fluoroscopy using a two-to-three-dimensional registration technique. Active knee flexion, femoral rotation and rollback were evaluated. The PROs were obtained after surgery using the 2011 Knee Society Scoring System (KSS), and their relationship with in vivo kinematics was determined.

Results: The average minimum and maximum flexion were -2.4 ± 7.3° and 113.2 ± 13.6°, respectively. The average femoral rotation was 7.4 ± 3.4°, and the average medial and lateral rollback were 2.4 ± 4.8 mm and 7.2 ± 5.6 mm, respectively. The multiple regression analysis revealed that the maximum flexion angle significantly contributed to symptoms and satisfaction. In addition, lateral rollback was also a significant factor affecting patient satisfaction. Lateral rollback and lateral Anterior-Posterior (AP) position at maximum flexion were correlated with the maximum flexion angle, whereas femoral rotation did not correlate with flexion angles.

Conclusions: Maximum flexion and lateral rollback are important for better patient satisfaction after TKA. To obtain the maximum flexion angle, it was necessary to perform the normal kinematic pattern with a large amount of lateral rollback.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10976802PMC
http://dx.doi.org/10.1186/s43019-024-00219-4DOI Listing

Publication Analysis

Top Keywords

maximum flexion
28
lateral rollback
24
patient satisfaction
16
in vivo kinematics
12
femoral rotation
12
flexion angle
12
flexion lateral
8
better patient
8
total knee
8
knee arthroplasty
8

Similar Publications

Shear wave elastography reveals passive and active mechanics of triceps surae muscles in vivo: From shear modulus-ankle angle to stress-strain characteristics.

J Appl Physiol (1985)

January 2025

Experimental Biomechanics Group, Institute of Structural Mechanics and Dynamics in Aerospace Engineering, Faculty of Aerospace Engineering and Geodesy, University of Stuttgart, Germany.

Characterizing individual muscle behavior is crucial for understanding joint function and adaptations to exercise, diseases, or aging. Shear wave elastography (SWE) is a promising tool for measuring the intrinsic material properties of muscle. This study assessed the passive and active shear modulus of the triceps surae muscle group in 14 volunteers (7 females, 25.

View Article and Find Full Text PDF

Barbell squats are commonly used in strength training, but the anterior-posterior displacement of the Center of Mass (COM) may impair joint stability and increase injury risk. This study investigates the key factors influencing COM displacement during different squat modes.; Methods: This study recruited 15 male strength training enthusiasts, who performed 60% of their one-repetition maximum (1RM) in the Front Barbell Squat (FBS), High Bar Back Squat (HBBS), and Low Bar Back Squat (LBBS).

View Article and Find Full Text PDF

Preoperative muscle atrophy leads to persistent gait abnormalities in patients undergoing total hip arthroplasty (THA). Efficient motor learning of the gluteus medius is crucial for their recovery. In this study, a single-joint hybrid assistive limb (HAL) was developed to assist hip abduction.

View Article and Find Full Text PDF

Background: We aimed to synthesize the kinematics and kinetics during landing and walking/running tasks of ankle copers compared with patients with chronic ankle instability and controls.

Methods: We systematically searched PubMed, CINAHL, SPORTDiscus, and Web of Science. Tri-planar lower extremity biomechanics (joint angle and moment at maximum and initial contact, and joint displacement) were synthesized using standard mean difference and 95 % confidence intervals.

View Article and Find Full Text PDF

Development and biomechanical evaluation of a 3D printed analogue of the human lumbar spine.

3D Print Med

January 2025

Musculoskeletal Biomechanics Research Lab, Department of Mechanical Engineering, McGill University, 845 Sherbrooke St. W (163), Montréal, QC, H3A 0C3, Canada.

Background: There exists a need for validated lumbar spine models in spine biomechanics research. Although cadaveric testing is the current gold standard for spinal implant development, it poses significant issues related to reliability and repeatability due to the wide variability in cadaveric physiologies. Moreover, there are increasing ethical concerns with human dissection practices.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!