This retrospective study aimed to compare objective/subjective torsion and other clinical characteristics of patients with acquired trochlear nerve palsy. This study included 82 consecutive patients who were diagnosed with acquired fourth cranial nerve palsy between 2014 and 2021 and who were followed up for ≥ 6 months. The etiologies, ocular deviation, objective and subjective torsions were reviewed. The etiologies were classified as ischemic, traumatic, brain lesion, idiopathic, or other. The patients were classified into two groups according to the recovery state: full recovery and partial/no-recovery. We compared the torsion and clinical features based on the etiology and recovery state. The average age was 59.1 ± 11.1 years, and 58 (71.0%) of the patients were male. The most common cause was ischemic (n = 49, 59.7%) and other common causes included traumatic (n = 16, 19.5%), brain lesion (n = 8, 9.8%), idiopathic (n = 5, 6.1%) and others (n = 4, 4.9%). Of the 82 patients, 56 (68.3%) were assigned to the full recovery group, and 26 (31.7%) were assigned to the partial/no-recovery group. The average age and number of patients with ischemic causes of palsy were greater in the full recovery group (p = 0.026 and p < 0.000, respectively). The vertical deviation angle, tilted angle on the Lancaster red-green test (LRGT), proportion of patients who experienced subjective torsion on the LRGT, and head tilt were smaller in the full recovery group (p = 0.037, 0.042, 0.045, and 0.006, respectively). Ischemic trochlear nerve palsy, advanced age, a small deviation angle at the primary position, and few cases of excyclotorsion on LRGT were characteristic of the full recovery group of acquired unilateral trochlear nerve palsy patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10973427 | PMC |
http://dx.doi.org/10.1038/s41598-024-58046-2 | DOI Listing |
J Hand Surg Glob Online
November 2024
The Curtis National Hand Center, MedStar Union Memorial Hospital, Baltimore, MD.
Purpose: Osteoporotic patients are at risk of peri-implant fractures after distal radius fixation. A unicortical screw in the proximal hole of the plate can theoretically decrease stress riser formation by eliminating the hole in the far bone cortex. This construct has been proposed in orthopedic literature to prevent peri-implant fractures but has not been tested in an osteoporotic distal radius model.
View Article and Find Full Text PDFTop Companion Anim Med
December 2024
OrtopediaVet Veterinary Clinic, Dr. Eloy Curuci and team. Volta Redonda Street, 670 - Campo Belo, São Paulo, State of São Paulo, Brazil, Zip code 04608-011.
Objectives: There is a lack of literature regarding the surgical management of high-grade patellar luxation in cats. Among the available options, corrective osteotomies are suitable for correcting severe bone deformities. Therefore, this study aimed to report on the surgical management of grade IV medial patellar luxation (MPL) through tibial corrective osteotomies in two cats.
View Article and Find Full Text PDFAm Fam Physician
December 2024
Indiana University School of Medicine, Indianapolis.
Acute abdominal pain in children is a common presentation in the clinic and emergency department settings and accounts for up to 10% of childhood emergency department visits. Determining the appropriate disposition of abdominal pain in children can be challenging. The differential diagnosis of acute abdominal pain, including gastroenteritis, constipation, urinary tract infection, acute appendicitis, tubo-ovarian abscess, testicular torsion, and volvulus, and the diagnostic approach vary by age.
View Article and Find Full Text PDFZhongguo Xiu Fu Chong Jian Wai Ke Za Zhi
December 2024
Department of Orthopedics, the Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou Sichuan, 646000, P. R. China.
Objective: To investigate ideal screw implant angle in reconstruction of tibiofibular syndesmosis injury by using a biomechanical test.
Methods: A total of 24 ankle specimens from adult cadavers were used as the tibiofibular syndesmosis injury model. According to the angle of screw placement, the tibiofibular syndesmosis injury models were randomly divided into groups A (0°), B (10°-15°), C (20°-25°), and D (30°-35°), and the screws were placed at a level 2 cm proximal to the ankle joint.
Cureus
November 2024
Orthopedics, Traumatology and Rehabilitation, International Islamic University Malaysia, Kuantan, MYS.
The increasing prevalence of proximal humerus fractures in the elderly population, particularly osteoporotic fractures, necessitates a biomechanical evaluation of Kirschner wire (K-wire) configurations used in percutaneous fixation. This study investigates the stability of different K-wire configurations and examines the effect of wire size and type (smooth vs. threaded).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!