The decoupled 8 × 2 transceiver array has been shown to achieve a mean B of 11.7 uT with a coefficient of variation of ~11% over the intracranial brain volume for 7-T MR imaging. However, this array may be thought to give lower signal-to-noise ratio (SNR) and higher g-factors for parallel imaging compared with a radio frequency (RF) receive-only coil due to the latter's higher coil count and use of coil overlap to reduce the mutual impedance. Nonetheless, because the transceiver's highly decoupled design (pertinent for transmission) should also be constructive for reception, we measured the noise correlation, g-factors, and SNR for the decoupled transceiver in comparison with a commercial reference coil. We found that although the transceiver has half the number of receive elements in comparison with the reference coil (16 vs. 32), comparable g-factors and SNR over the head were obtained. From five subjects, the transceiver versus reference coil SNR was 65 ± 10 versus 67 ± 15. The mean noise correlation for all coil pairs was 10% ± 5% and 12% ± 9% (transceiver and reference coil, respectively). As changes in load impedance may alter the S parameters, we also examined the performance of the transceiver with tuned and matched (TM) versus untuned and unmatched (UTM) conditions on five subjects. We found that the noise correlation and SNR are robust to load variation; a noise correlation of 10% ± 5% and 10% ± 6% was determined with TM versus UTM conditions (SNR/SNR = 0.97 ± 0.08). Finally, we demonstrate the performance of the array in human brain using T2-weighted turbo spin echo imaging, finding excellent SNR performance in both caudal and rostral brain regions.

Download full-text PDF

Source
http://dx.doi.org/10.1002/nbm.5146DOI Listing

Publication Analysis

Top Keywords

noise correlation
16
reference coil
16
8 × 2 transceiver
8
transceiver array
8
coil
8
g-factors snr
8
utm conditions
8
transceiver
7
snr
6
evaluation performance
4

Similar Publications

True total-body and extended axial field-of-view (AFOV) PET/CT with 1m or more of body coverage are now commercially available and dramatically increase system sensitivity over conventional AFOV PET/CT. The Siemens Biograph Vision Quadra (Quadra), with an AFOV of 106cm, potentially allows use of significantly lower administered radiopharmaceuticals as well as reduced scan times. The aim of this study was to optimise acquisition protocols for routine clinical imaging with FDG on the Quadra the prioritisation of reduced activity given physical infrastructure constraints in our facility.

View Article and Find Full Text PDF

Psychophysical assessment of color vision with the Cambridge Color Vision Test in unilateral functional amblyopia.

Arq Bras Oftalmol

January 2025

Research Nucleus in Neuroscience and Behavior and Applied Neuroscience, Universidade de São Paulo, São Paulo, SP, Brazil.

Purpose: Amblyopia is a cortical neurological disorder caused by abnormal visual experiences during the critical period for visual development. Recent works have shown that, in addition to the well-known visual alterations, such as changes in visual acuity, several perceptual aspects of vision are affected. This study aims to analyze and compare the effects of different types of amblyopia on visual color processing and determine whether these effects are correlated with visual acuity.

View Article and Find Full Text PDF

Background: Bipolar Disorder (BD) is a complex disease. It is heterogeneous, both at the phenotypic and genetic level, although the extent and impact of this heterogeneity is not fully understood. One way to assess this heterogeneity is to look for patterns in the subphenotype data.

View Article and Find Full Text PDF

We introduce an approach for analyzing the responses of dynamical systems to external perturbations that combines score-based generative modeling with the generalized fluctuation-dissipation theorem. The methodology enables accurate estimation of system responses, including those with non-Gaussian statistics. We numerically validate our approach using time-series data from three different stochastic partial differential equations of increasing complexity: an Ornstein-Uhlenbeck process with spatially correlated noise, a modified stochastic Allen-Cahn equation, and the 2D Navier-Stokes equations.

View Article and Find Full Text PDF

The identification of vibration and reconstruction of sound fields of plate structures are important for understanding the vibroacoustic characteristics of complex structures. This paper presents a data-physics driven (DPD) model integrated with transfer learning (DPDT) for high-precision identification and reconstruction of vibration and noise radiation of plate structures. The model combines the Kirchhoff-Helmholtz integral equation with convolutional neural networks, leveraging physical information to reduce the need for extensive data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!