Many patients exhibit persistently reduced pulmonary diffusing capacity after coronavirus disease 2019 (COVID-19). In this study, dual test gas diffusing capacity for carbon monoxide and nitric oxide (D) metrics and their relationship to disease severity and physical performance were examined in patients who previously had COVID-19. An initial cohort of 148 patients diagnosed with COVID-19 of all severities between March 2020 and March 2021 had a D measurement performed using the single-breath method at 5.7 months follow-up. All patients with at least one abnormal D metric (n = 87) were revaluated at 12.5 months follow-up. The D was used to provide the pulmonary diffusing capacity for nitric oxide (D), the pulmonary diffusing capacity for carbon monoxide (D), the alveolar-capillary membrane diffusing capacity and the pulmonary capillary blood volume. At both 5.7 and 12.5 months, physical performance was assessed using a 30 s sit-to-stand test and the 6 min walk test. Approximately 60% of patients exhibited a severity-dependent decline in at least one D metric at 5.7 months follow-up. At 12.5 months, both D and D had returned towards normal but still remained abnormal in two-thirds of the patients. Concurrently, improvements in physical performance were observed, but with no apparent relationship to any D metric. The severity-dependent decline in D and D observed at 5.7 months after COVID-19 appears to be reduced consistently at 12.5 months follow-up in the majority of patients, despite marked improvements in physical performance.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11061629 | PMC |
http://dx.doi.org/10.1113/EP091757 | DOI Listing |
It has been shown that light speckle fluctuations provide a means for noninvasive measurements of cerebral blood flow index (CBFi). While conventional Diffuse Correlation Spectroscopy (DCS) provides marginal brain sensitivity for CBFi in adult humans, new techniques have recently emerged to improve diffuse light throughput and thus, brain sensitivity. Here we further optimize one such approach, interferometric diffusing wave spectroscopy (iDWS), with respect to number of independent channels, camera duty cycle and full well capacity, incident power, noise and artifact mitigation, and data processing.
View Article and Find Full Text PDFSmall
January 2025
National and Local Joint Engineering Laboratory for Lithium-ion Batteries and Materials Preparation Technology, Key Laboratory of Advanced Battery Materials of Yunnan Province, Faculty of Metallurgical and Energy Engineering, Faculty of Materials Science and Engineering, Kunming University of Science and Technology, Kunming, 650093, China.
Owing to its abundant manganese source, high operating voltage, and good ionic diffusivity attributed to its 3D Li-ion diffusion channels. Spinel LiMnO is considered a promising low-cost positive electrode material in the context of reducing scarce elements such as cobalt and nickel from advanced lithium-ion batteries. However, the rapid capacity degradation and inadequate rate capabilities induced by the Jahn-Teller distortion and the manganese dissolution have limited the large-scale adoption of spinel LiMnO for decades.
View Article and Find Full Text PDFAdv Mater
January 2025
Materials Science and Engineering Program, Walker Department of Mechanical Engineering and Texas Materials Institute, The University of Texas at Austin, Austin, TX, 78712, USA.
Anode-free all solid-state batteries (AF-ASSBs) employ "empty" current collector with three active interfaces that determine electrochemical stability; lithium metal - Solid electrolyte (SE) interphase (SEI-1), lithium - current collector interface, and collector - SE interphase (SEI-2). Argyrodite LiPSCl (LPSCl) solid electrolyte (SE) displays SEI-2 containing copper sulfides, formed even at open circuit. Bilayer of 140 nm magnesium/30 nm tungsten (Mg/W-Cu) controls the three interfaces and allows for state-of-the-art electrochemical performance in half-cells and fullcells.
View Article and Find Full Text PDFNat Commun
January 2025
Chemical Sciences and Engineering Division, Argonne National Laboratory, Lemont, IL, USA.
Recent efforts to reduce battery costs and enhance sustainability have focused on eliminating Cobalt (Co) from cathode materials. While Co-free designs have shown notable success in polycrystalline cathodes, their impact on single crystalline (SC) cathodes remains less understood due to the significantly extended lithium diffusion pathways and the higher-temperature synthesis involved. Here, we reveal that removing Co from SC cathodes is structurally and electrochemically unfavorable, exhibiting unusual voltage fade behavior.
View Article and Find Full Text PDFRMD Open
January 2025
Service de Rhumatologie, Hôpital Cochin, APHP-Centre Université Paris Cité, Paris, France
Objective: To examine the course of interstitial lung disease associated with rheumatoid arthritis (RA-ILD) in France on treatment with Janus kinase inhibitors (JAKis) using the MAJIK-SFR registry.
Methods: Prospective national multicentre observational study identifying patients with RA-ILD from the MAJIK-SFR registry. Pulmonary assessment data were collected at JAKi initiation and follow-up visits (6 months, 12 months and a median of 21 months postinclusion), including chest high-resolution CT (HRCT), pulmonary function tests (forced vital capacity (FVC) and diffusing capacity of the lungs for carbon monoxide (DLCO)), acute exacerbations of ILD, respiratory infections and lung cancers.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!