Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The periparturient period for dairy cows is a metabolically dynamic time period where the cow is adjusting from gestation to the onset of lactation. Metabolic disorders such as ketosis, hypocalcemia, and fatty liver occur during this time; however, tools to diagnose these diseases on-farm is limited. The need for compact metabolite quantification devices that can quantify metabolites on farm from whole blood samples is warranted. The purpose of this study was to validate a portable blood analyzer (PBA) by analyzing metabolites on privately owned dairy farms in southcentral Wisconsin. Additional tests were completed to determine if plasma metabolite quantification was similar to whole-blood quantification. Two phases were conducted on two separate farms to complete these analyses and data were analyzed by Bland-Altman plot and correlations. Metabolites quantified from whole blood samples included albumin, alanine and aspartate aminotransferases, β-hydroxybutyrate, blood urea nitrogen, total calcium, cholesterol, creatinine kinase, γ-glutamyl transferase, glucose, magnesium, nonesterified fatty acids, phosphorous, and total protein and were analyzed in the lab after plasma separation to determine gold-standard laboratory concentrations. Across Phase 1 and 2, whole-blood PBA metabolite concentrations resulted in similar results compared to the laboratory assays. For plasma analyzed on the PBA, overall results were positively correlated, but robustness was dependent upon initial validation results indicating some metabolites are suitable for plasma quantification on the device. These results indicate that the PBA is a viable on-farm metabolite quantification tool that will be valuable for on-farm diagnosis of metabolic stress and dysfunction in transition dairy cows.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.rvsc.2024.105228 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!