This study evaluated the clinical survival rates of 170 Morse taper implants through clinical and mechanical parameters in different therapeutic approaches such as single crowns, fixed partial prostheses, and fixed full-arch prostheses. Patients referred to the Center on Education and Research on Dental Implants from May 2017 to July 2018 with the indication for dental implant therapy, aged >18 years, without periodontal disease, recent evidence of inflammatory activity or other oral disorders, current pregnancy, uncontrolled diabetes mellitus or heavy smoking habit were included in this study. After 12 weeks of healing since the implants were placed in the mandible and after 16 weeks following implants placed in the maxilla, patients returned to the Center for prosthetic rehabilitation. After implant therapy, all patients underwent periodical, clinical, and prosthetic examinations every 6 months. Prosthetic restorations involved 109 fixed reconstructions in function. Few prosthetic complications were reported (6.55%). Twenty implants were rehabilitated with cemented prostheses; from those, 1 crown suffered a loss in retention/decementation. Of the 148 implants rehabilitated with screwed-retained prostheses, 6.76% suffered prosthetic screw loosening. The cumulative implant survival rate was 98.2%. When peri-implant tissue health was evaluated, the keratinized mucosa band appeared related to peri-implant tissue stability. Thus, Morse taper implants represented a successful procedure for implant rehabilitation, with a high cumulative implant survival rate, low prevalence of biological and prosthetic complications, and good stability of peri-implant tissues over the assessed period.

Download full-text PDF

Source
http://dx.doi.org/10.1563/aaid-joi-D-23-00054DOI Listing

Publication Analysis

Top Keywords

morse taper
12
taper implants
12
implants
8
implant therapy
8
prosthetic complications
8
implants rehabilitated
8
cumulative implant
8
implant survival
8
survival rate
8
peri-implant tissue
8

Similar Publications

The purpose of this study was to evaluate the effect of a single dose of ionizing radiation (30 Gy) on the osseointegration of implants in the rabbit tibia. Twenty rabbits received two dental Morse-tapered junction implants and one implant in each tibia. The animals were randomly divided into two groups (n=10), non-irradiated (NoIr) and irradiated (Ir), wherein the Ir group received a single dose of 30 Gy radiation 2 weeks after implant installation.

View Article and Find Full Text PDF

Statement Of Problem: The biomechanical stability of the implant-prosthesis assembly and its maintenance under function is a determining factor in the success of implant prosthesis rehabilitation, but studies of different angular tapers are lacking.

Purpose: The purpose of this in vitro study was to evaluate the axial displacement and torque loss of prosthetic abutments with Morse-type connections of different angular tapers after thermomechanical cycling by using microcomputed tomography (µCT) and a digital torque wrench.

Material And Methods: Eighteen Ø3.

View Article and Find Full Text PDF

The present study evaluated the mechanical behavior of five designs of Morse taper (MT) connections with and without the application of loads. For this, the detorque of the fixing screw and the traction force required to disconnect the abutment from the implant were assessed. A total of 100 sets of implants/abutments (IAs) with MT-type connections were used, comprising five groups ( = 20/group): (1) Group Imp 11.

View Article and Find Full Text PDF

The objective of this study was to evaluate microbial leakage by means of genome counts, through the implant-abutment interface in dental implants with different Morse taper abutments. Fifty-six samples were prepared and divided in four groups: CMC TB (14 Cylindrical Implants-14 TiBase Abutments), CMX TB (14 Conical Implants-14 TiBase Abutments), CMX PU (14 Conical Implants-14 Universal Abutment) and CMX U (14 Tapered Implants-14 UCLA Abutments). Assemblies had their interface submerged in saliva as the contaminant.

View Article and Find Full Text PDF

Objectives: This test aimed to investigate the factors affecting the locking force between the implant and abutment and the amount of abutment subsidence in pure Morse taper connection implant systems.

Methods: With reference to the Bicon implant abutment connection design, different types of implant specimens and their corresponding types of abutments were fabricated. The implant-abutment locking taper was uniformly 1.

View Article and Find Full Text PDF