A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pharmacokinetic and pharmacodynamic evaluation study of etomidate: a randomized, open-label, 2-period crossover study in healthy Chinese subjects. | LitMetric

Etomidate is a sedative and hypnotic drug through intravenous administration that act on the central nervous system through GABA (Gamma-Amino Butyric Acid) receptors, which is widely used in anesthesia induction and maintenance and long-term sedation in severe patients. The study aimed to evaluate the pharmacokinetic and pharmacodynamic properties of two etomidate fat emulsions after administration through the intravenous infusion pump in healthy Chinese subjects. A randomized, open-label, 2-period crossover study was performed in 52 healthy subjects. The wash-out period was 7 days. Blood samples and pharmacodynamic index values were collected at the specified time points. Etomidate concentrations were measured using validated liquid chromatography-tandem mass spectrometry. Pharmacokinetic parameters were analyzed using a non-compartment model method. Pharmacodynamic parameters were calculated using pharmacodynamic index values. The study also evaluated the safety of the etomidate. Both the pharmacokinetic parameters and pharmacodynamic parameters result of the test and reference formulation were very similar. The 90% confidence intervals (CI) of the geometric least-squares mean (GLSM) ratios of the test to reference formulation were 91.33-104.96% for the maximum plasma concentration (C), 97.21-102.03% for the area under the plasma concentration time curve from time 0 to the time of the last measurable concentration (AUC), and 97.22-102.33% for the area under the plasma concentration time curve from time 0 to infinity (AUC). Meanwhile, the 90% CI of the GLSM ratios of the test to reference formulation were 102.28-110.69% for the minimal BIS value (BIS), 99.23-101.17% for the area under the BIS time curve from time 0-60 min after administration (BISAUC), respectively. The 90% CI of these pharmacokinetic and pharmacodynamic parameters all fall in the accepted bioequivalence range of 80.00-125.00%. No serious adverse events occurred during the study. This study has shown that the etomidate fat emulsion test and reference formulation had similar pharmacokinetic and pharmacodynamic characteristics in vivo. The two formulations exhibited good safety and well-tolerance.Clinical trials registration number: http://www.chinadrugtrials.org.cn/index.html . # CTR20191836.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10963774PMC
http://dx.doi.org/10.1038/s41598-024-57581-2DOI Listing

Publication Analysis

Top Keywords

pharmacokinetic pharmacodynamic
16
test reference
16
reference formulation
16
pharmacodynamic parameters
12
plasma concentration
12
time curve
12
curve time
12
study etomidate
8
randomized open-label
8
open-label 2-period
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!