Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
To investigate the value of metagenomic next-generation sequencing (mNGS) in the diagnosis of Pneumocystis jirovecii pneumonia (PJP) in patients undergoing allogeneic hematopoietic stem cell transplantation (allo-HSCT) . The data of 98 patients with suspected pulmonary infection after allo-HSCT who underwent pathogen detection from bronchoalveolar lavage fluid between June 2016 and August 2023 at Nanfang Hospital were analyzed. The diagnostic performance of mNGS, conventional methods, and real-time quantitative polymerase chain reaction (qPCR) for PJP were compared. A total of 12 patients were diagnosed with PJP, including 11 with a proven diagnosis and 1 with a probable diagnosis. Among the patients with a proven diagnosis, 1 was positive by both conventional methods and qPCR, and 10 were positive by qPCR only. Pneumocystis jirovecii was detected by mNGS in all 12 patients. The diagnostic sensitivity of mNGS for PJP was 100%, which was greater than that of conventional methods (8.3%, =0.001) and similar to that of qPCR (91.6%, =1.000) . A total of 75% of the patients developed mixed pulmonary infections, and cytomegalovirus and Epstein-Barr virus were the most common pathogens. Mixed infection was detected in eight patients by mNGS and in five patients by qPCR, but not by conventional methods (=0.008) . mNGS had good sensitivity for diagnosing PJP after allo-HSCT and was advantageous for detecting mixed infectious pathogens; therefore, mNGS might be an effective supplement to regular detection methods and qPCR.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10951114 | PMC |
http://dx.doi.org/10.3760/cma.j.cn121090-20230928-00147 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!