A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Utility of articulating instruments as an alternative to robotic devices in laparoscopic right hemicolectomy. | LitMetric

Unlabelled: Laparoscopic complete mesocolic excision with central vessel ligation has been widely accepted for its oncological benefits in colon cancer surgery. However, laparoscopic right hemicolectomy involves a risk for vascular injury during dissection around the surgical trunk. This technical difficulty has been attributed to the limited movement of conventional laparoscopic forceps. Although robotic devices can overcome the restricted motion of laparoscopic devices, they are not yet widely used. The ArtiSential is an articulating laparoscopic instrument that has a two-joint end-effector that enables a wide range of motion precisely reflecting the surgeon's finger movements, and is designed to compensate for the drawbacks of conventional laparoscopic tools. The present study demonstrated the utility of articulating instruments in laparoscopic right hemicolectomy by comparing the authors' laparoscopic procedures, using articulating instruments, with robotic procedures. Articulating laparoscopic instruments can be successfully maneuvered in virtually the same manner as robotic devices and, as such, represent a viable alternative to robotic surgery.

Supplementary Information: The online version contains supplementary material available at 10.1007/s13691-024-00654-w.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10957826PMC
http://dx.doi.org/10.1007/s13691-024-00654-wDOI Listing

Publication Analysis

Top Keywords

articulating instruments
12
robotic devices
12
laparoscopic hemicolectomy
12
laparoscopic
10
utility articulating
8
alternative robotic
8
conventional laparoscopic
8
articulating laparoscopic
8
procedures articulating
8
robotic
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!