Statement Of Problem: A working knowledge of the analytical capacities of contemporary registration methods is essential for prosthetic treatment; however, there is a paucity of studies which coherently investigate the capabilities and limitations of the various diagnostic procedures utilized for prosthetic occlusion.

Purpose: The present prospective clinical study aimed to evaluate the similarities and differences among contemporary registration methods through comparative analysis.

Material And Methods: The habitual static occlusion of 19 healthy individuals (14 women; mean age ± standard deviation, 30.8 ± 4.8 years) was analyzed 3 times a day, using shimstock foil, occlusal foil, wax registration, silicone registration, and computerized registration. The procedures were repeated after 14 days. Statistical analyses included all registrations referencing the first measurement point to assess the mean values of antagonistic contacts and the differences between these measurements. Pearson's and Kendall's correlation analyses were performed as part of the coherent mixed logistic regression model, and marginal probabilities were calculated using the registration technique and repeated measurements.

Results: Strong correlations were found among the various registration techniques. The largest effect sizes were observed among the wax, silicone, occlusion foil, and computerized registrations (r = 0.95,  < 0.001 to r = 0.62,  < 0.001), while the lowest effect sizes were found for shimstock correlations (τ = 0.41,  < 0.001 to τ = 0.27,  < 0.001). Occlusal changes per maxillary arch were observed referencing the first measurement time with wax registration ( < 0.001; 7.4%), shimstock foil ( < 0.001; 13.8%), computerized registration ( < 0.001; 20.3%), silicone registration ( = 0.009; 66.3%), and occlusion foil ( < 0.001; 98.8%). Occlusal changes per maxillary tooth were observed from the first incisor ( < 0.001; 5.7%) to the third molar ( < 0.001; 18.1%).

Conclusions: The results of the present study revealed that there are strong overall correlations among the various contemporary registration techniques. The different affinities of the techniques used to register occlusal changes, however, showed differences in the measurement techniques, which should be neither over- nor underestimated. The differential tendencies of teeth to change should be considered, even if a hypervariable system is assumed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10958416PMC
http://dx.doi.org/10.1016/j.heliyon.2024.e28130DOI Listing

Publication Analysis

Top Keywords

static occlusion
8
contemporary registration
8
registration methods
8
registration
7
register static
4
occlusion correlation
4
correlation contemporary
4
contemporary techniques
4
techniques statement
4
statement problem
4

Similar Publications

Aim: This study aimed to evaluate OccluSense's reliability against conventional articulating films in assessing static occlusion. The study also targets to identify possible limitations and influencing factors when using this device to asses static occlusion.

Materials And Methods: This experimental research utilized twenty epoxy resin typodont models representing various occlusal discrepancies.

View Article and Find Full Text PDF

Predicting the location of moving objects in noisy environments is essential to everyday behavior, like when participating in traffic. Although many objects provide multisensory information, it remains unknown how humans use multisensory information to localize moving objects, and how this depends on expected sensory interference (e.g.

View Article and Find Full Text PDF

Background: Examining stress distributions in abutment teeth with periapical lesions is essential for understanding their biomechanical impact on dental structures and tissues. This study uses finite element analysis (FEA) to evaluate these stress patterns under occlusal forces, aiming to enhance treatment strategies and prosthetic designs.

Methods: Three FEA models were created: a healthy mandibular premolar (Model 1), a premolar with a single crown and a lesion repaired using a fiber-post (Model 2), and 3) a premolar with a lesion repaired using fiber-post to support a four-member bridge (Model 3).

View Article and Find Full Text PDF

For surveillance video management in university laboratories, issues such as occlusion and low-resolution face capture often arise. Traditional face recognition algorithms are typically static and rely heavily on clear images, resulting in inaccurate recognition for low-resolution, small-sized faces. To address the challenges of occlusion and low-resolution person identification, this paper proposes a new face recognition framework by reconstructing Retinaface-Resnet and combining it with Quality-Adaptive Margin (adaface).

View Article and Find Full Text PDF

Nucleosome dynamics render heterochromatin accessible in living human cells.

bioRxiv

December 2024

Division of Developmental Biology, Eunice Kennedy-Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda MD 20892, USA.

The eukaryotic genome is packaged into chromatin, which is composed of a nucleosomal filament that coils up to form more compact structures. Chromatin exists in two main forms: euchromatin, which is relatively decondensed and enriched in transcriptionally active genes, and heterochromatin, which is condensed and transcriptionally repressed . It is widely accepted that chromatin architecture modulates DNA accessibility, restricting the access of sequence-specific, gene-regulatory, transcription factors to the genome.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!