A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A two-year comparison of reverse total shoulder arthroplasty mini-humeral tray and augmented mini-glenoid baseplate implants vs. standard implants. | LitMetric

Background: Patients who undergo reverse total shoulder arthroplasty (RTSA) are getting younger with greater function expectations. This retrospective, longitudinal study of prospectively collected data compared perceived shoulder function and strength, active shoulder mobility, radiographic evidence of scapular notching, and implant survival over the initial 2-years post-RTSA among patient groups who received either standard central fixation point liner and glenoid baseplate implants, or lower size profile mini-humeral tray with offset trunnion options and mini-augmented glenoid baseplate implants.

Materials And Methods: Patients who underwent primary RTSA using standard central fixation point liner and glenoid baseplate implants (Group 1, n = 180) were compared with patients who underwent primary RTSA using lower size profile mini-humeral tray with offset trunnion options and mini-augmented glenoid baseplate implants (Group 2, n = 53) for active shoulder mobility, American Shoulder and Elbow Surgeons (ASES) score, perceived ability to lift 10 lbs (4.5 kg) overhead, radiographic evidence of scapular notching, and implant survival. Data was collected pre-surgery, 6-weeks, 6-months, 1-year, and 2-years post-RTSA (p ≤ 0.05).

Results: More Group 2 patients had more complex B or C Walch glenoid morphology, while Group 1 had more A1 or A2 types (p ≤ 0.001). Group 2 had greater active shoulder flexion at 6-months, 1-year, and 2-years (p ≤ 0.018) and external rotation (in adduction) at 6-months and 2-years (p ≤ 0.004) compared to Group 1, with higher ASES scores at 6-months and 2-years (p ≤ 0.026) (with small-to-medium effect sizes), and with more patients meeting or exceeding the minimal clinically important difference (MCID) at 2-years (p = 0.045) and patient acceptable symptomatic state (PASS) levels at 6-months, 1-year and 2-years (p ≤ 0.045). Scapular notching was identified in six of 53 (11.3%) Group 2 patients and in 32 of 180 (17.7%) Group 1 patients. Group 1 patients had more grade 2 or greater scapular notching grades compared to Group 2 (p = 0.04). Implant survival was comparable with Group 1 = eight of 180 (4.4%) and Group 2 = 1 of 53 (1.9%) of patients requiring removal for 95.6% and 98.1% implant survival, respectively.

Conclusion: Limited scapular notching and excellent implant survival was observed in both groups. Despite including individuals with more complex glenoid deficiency, patients receiving the lower size profile implants generally displayed better active shoulder mobility and perceived shoulder function compared to those who received standard implants. These patients also more frequently met or exceeded the MCID by 2-years post-RTSA and PASS levels by 6-months, 1-year, and 2-years post-RTSA, with lower scapular notching grades.

Level Of Evidence: Retrospective comparative study.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00402-024-05276-8DOI Listing

Publication Analysis

Top Keywords

scapular notching
24
implant survival
20
baseplate implants
16
active shoulder
16
2-years post-rtsa
16
glenoid baseplate
16
6-months 1-year
16
1-year 2-years
16
group patients
16
mini-humeral tray
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!