Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate the safety and long-term clinical outcomes of stent-graft placement to treat hepatic arterial hemorrhage after pancreaticobiliary surgery.
Materials And Methods: Outcomes were retrospectively evaluated in 61 patients (50 men and 11 women; mean age, 63 years) who underwent stent-graft placement for delayed arterial hemorrhage (after 24 hours) after pancreaticobiliary surgery from 2006 to 2023. Bleeding sites included the gastroduodenal artery stump (n = 54), common or proper hepatic artery (n = 5), and right hepatic artery (n = 2). The stent-grafts used were Viabahn (n = 27), Comvi (n = 11), Jostent (n = 3), Covera (n = 11), and Lifestream (n = 7). Technical and clinical success and adverse events (AE) were evaluated. After stent-graft placement, overall survival (OS), hemorrhage-free survival (HFS), and stent patency were evaluated.
Results: The technical and clinical success rates of stent-graft placement were 97% and 93%, respectively. The severe AE rate was 12% and was significantly higher in patients who underwent pylorus-sacrificing rather than pylorus-preserving surgery (P = .001). None of the severe AEs were associated with patient mortality. Median OS after stent-graft placement was 854 days, and median HFS was 822 days. The 1-, 3-, 5-, and 10-year stent patency rates were 87%, 84%, 79%, and 72%, respectively.
Conclusions: Stent-graft placement was safe and provided long-term control of hepatic arterial hemorrhage after pancreaticobiliary surgery.