Significance: The reprojection setup typical of oblique plane microscopy (OPM) limits the effective aperture of the imaging system, and therefore its efficiency and resolution. Large aperture system is only possible through the use of custom specialized optics. A full-aperture OPM made with off the shelf components would both improve the performance of the method and encourage its widespread adoption.

Aim: To prove the feasibility of an OPM without a conventional reprojection setup, retaining the full aperture of the primary objective employed.

Approach: A deformable lens based remote focusing setup synchronized with the rolling shutter of a complementary metal-oxide semiconductor detector is used instead of a traditional reprojection system.

Results: The system was tested on microbeads, prepared slides, and zebrafish embryos. Resolution and pixel throughput were superior to conventional OPM with cropped apertures, and comparable with OPM implementations with custom made optical components.

Conclusions: An easily reproducible approach to OPM imaging is presented, eliminating the conventional reprojection setup and exploiting the full aperture of the employed objective.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10956707PMC
http://dx.doi.org/10.1117/1.JBO.29.3.036502DOI Listing

Publication Analysis

Top Keywords

reprojection setup
12
oblique plane
8
plane microscopy
8
remote focusing
8
conventional reprojection
8
full aperture
8
opm
6
full-aperture extended-depth
4
extended-depth oblique
4
microscopy dynamic
4

Similar Publications

Significance: The reprojection setup typical of oblique plane microscopy (OPM) limits the effective aperture of the imaging system, and therefore its efficiency and resolution. Large aperture system is only possible through the use of custom specialized optics. A full-aperture OPM made with off the shelf components would both improve the performance of the method and encourage its widespread adoption.

View Article and Find Full Text PDF

Fringe projection profilometry is an efficient and accurate technique for three-dimensional (3D) measurement to calibrate a camera and projector setup. The feature centers of circles on a calibration board are extracted on the camera image plane and mapped to the projector image plane during the calibration procedure. The accuracy of the mapping between camera pixels and projector pixels is crucial to the calibration accuracy, which directly affects the measurement precision of the system.

View Article and Find Full Text PDF

Semantic segmentation is used to enable a computer to understand its surrounding environment. In image processing, images are partitioned into segments for this purpose. State-of-the-art methods make use of Convolutional Neural Networks to segment a 2D image.

View Article and Find Full Text PDF

Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes.

Sensors (Basel)

December 2020

Dipartimento di Ingegneria Civile e Industriale, Università di Pisa, Largo Lucio Lazzarino 1, 56122 Pisa, Italy.

Rotary tables are often used to speed up the acquisition time during the 3D scanning of complex geometries. In order to avoid manual registration of the point clouds acquired with different orientations, automatic algorithms to compensate the rotation were developed. Alternatively, a proper calibration of the rotary axis with respect to the camera system is needed.

View Article and Find Full Text PDF

For patient setup of the IGRT technique, various imaging systems are currently available. MV portal imaging is performed in identical geometry with the treatment beam so that the portal image provides accurate geometric information. However, MV imaging suffers from poor image contrast due to larger Compton scatter photons.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!