AI Article Synopsis

Article Abstract

Few reports exist on the treatment of transverse patellar fractures (TPFs) using absorbable cannulated screws and high-strength sutures, and most screws and sutures lack good biomechanics and clinical trials. Therefore, this study aimed to demonstrate the biomechanical stability and clinical efficacy of tension-band high-strength sutures combined with absorbable cannulated screws (TBSAS) in treating TPFs (AO/OTA 34 C1). Finite element models of five internal fixation schemes were established: tension-band wire with K-wire (TBW), TBW with cerclage wire (TBWC), TBW with headless pressure screws (TBWHS), TBW with full-thread screws (TBWFS), and TBSAS. We comprehensively compared the biomechanical characteristics of the TBSAS treatment scheme during knee flexion and extension. Forty-one patients with TPFs in our hospital between January 2020 and August 2022 were retrospectively enrolled and divided into the TBSAS ( = 22) and TBWC ( = 19) groups. Clinical and follow-up outcomes, including operative time, visual analog scale (VAS) pain score, postoperative complications, Bostman score, and final knee range of motion, were compared between both groups. Finite element analysis (FEA) showed that TBWHS and TBWFS achieved the minimum mean fracture interface relative displacement during knee flexion (45°, 0-500 N bending load) and full extension (0°, 0-500 N axial load). There was no significant difference between TBSAS (0.136 mm) and TBWC (0.146 mm) during knee flexion (500 N); however, TBSAS displacement was smaller (0.075 mm) during full extension (500 N). Furthermore, the stress results for the internal fixation and the patella were generally lower when using TBSAS. Retrospective clinical studies showed that the TBSAS group had a shorter operative time, lower VAS pain score at 1 and 2 months postoperatively, better Bostman knee function score at 3 and 9 months postoperatively, and better final knee joint motion than the TBWC group (all < 0.05). There were five cases (26.3%) of internal fixation stimulation complications in the TBWC group. TBSAS demonstrated excellent safety and effectiveness in treating TPFs. It is sufficient to meet the needs of TPF fixation and early functional exercise and effectively reduces metal internal fixation-induced complications and secondary surgery-induced trauma.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10955129PMC
http://dx.doi.org/10.3389/fbioe.2024.1340482DOI Listing

Publication Analysis

Top Keywords

absorbable cannulated
12
cannulated screws
12
finite element
12
internal fixation
12
knee flexion
12
tbsas
9
combined absorbable
8
transverse patellar
8
patellar fractures
8
element analysis
8

Similar Publications

Background: Bioresorbable scaffolds (BRS) were developed to overcome limitations related to late stent failures of drug-eluting stents, but lumen reductions over time after implantation of BRS have been reported. This study aimed to investigate if lesion preparation with a scoring balloon compared with a standard noncompliant balloon minimizes lumen reduction after implantation of a Magmaris BRS assessed with optical coherence tomography and intravascular ultrasound.

Methods: Eighty-two patients with stable angina were randomized in a ratio of 1:1 to lesion preparation with a scoring balloon versus a standard noncompliant balloon before implantation of a Magmaris BRS.

View Article and Find Full Text PDF

Background: In cattle, dietary choline is fed in a rumen-protected form to bypass ruminal degradation while allowing intestinal absorption of choline. We require data to help us define choline utilization in the dairy cow transitioning from gestation to lactation.

Objectives: The study examined choline methyl group transfer in dairy cattle transitioning from gestation to lactation.

View Article and Find Full Text PDF

Gardenia blue (GB), a widely used plant-derived food color is prepared by reaction of genipin, the aglycone of geniposide, with protein hydrolysate. Recent animal studies investigating GB toxicity have indicated blue coloration in the gastrointestinal tract, kidneys and mesenteric lymph nodes in rodents following dietary administration. This study investigated the uptake and disposition of [C]GB in male and female rats and mice administered 100 or 1000 mg/kg by gavage.

View Article and Find Full Text PDF
Article Synopsis
  • A multicenter study is assessing the safety and effectiveness of a cutting balloon angioplasty combined with a bioabsorbable polymer-coated everolimus-eluting stent for treating calcified coronary artery lesions in patients.
  • The trial involves comparing the cutting balloon (Wolverine™) to a non-compliant balloon in a group of 250 patients who have received the Synergy™ stent, focusing on outcomes like stent area, major cardiac events, and operational metrics.
  • The research aims to validate the use of cutting balloons for a range of calcified lesions, potentially influencing insurance coverage for these procedures.
View Article and Find Full Text PDF
Article Synopsis
  • Sequential intermediate kissing balloon dilation (sIKBD) improves the effectiveness of crush stenting, but optimal procedures for its use are still uncertain.
  • This study assessed the impact of sIKBD on mini-crush stenting (mini-CS) using different types of stents in bifurcation models and employed advanced imaging techniques for analysis.
  • Results indicated that incorporating sIKBD led to better outcomes, including reduced stent malapposition and less stenosis in side-branches, particularly with metal drug-eluting stents compared to bioresorbable scaffolds.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!