AI Article Synopsis

  • Regular cleaning of transit vehicle surfaces is essential but challenging due to operational needs, leading to the exploration of copper alloys as an antimicrobial solution.
  • Over a year, three types of copper products were tested on public transit vehicles in Vancouver and Toronto, showing significant reductions in bacterial counts (42.7%) and ATP bioluminescence (87.1%) compared to control surfaces.
  • The copper products maintained their antimicrobial effectiveness and structural integrity over the 12 months, despite some carbon buildup on the surfaces.

Article Abstract

Surfaces on transit vehicles are frequently touched and could potentially act as reservoirs for micro-organism transmission. Regular cleaning and disinfection to minimize the spread of micro-organisms is operationally challenging due to the need to keep vehicles in circulation. The application of copper (Cu) alloys to high- touch surfaces could help reduce the risk of cross-contamination, however, little is known about the durability and efficacy of engineered copper surfaces after prolonged use. Three Cu products (decal, thermal fabrication, and alloy covers) were assessed over a 12-month period. These Cu products were randomly installed on 110 stanchions on three buses and four train (SkyTrain) cars in Vancouver and three buses, two subway cars, and two streetcars in Toronto with mirrored control surfaces directly opposite. Bacterial counts (Colony forming units, CFU) and ATP bioluminescence (ATPB) were measured every two months after peak morning routes. Durability of the Cu products were assessed monthly through visual inspection and colorimetry assays or by ex-situ microscopy. Cu products on stanchions reduced the mean colony forming units (CFU) of all vehicles by 42.7% in the mean CFU (0.573 (CI 95% 0.453-0.726), p-value < 0.001) compared to control surfaces. The three Cu products exhibited an overall 87.1% reduction in the mean ATPB readings (0.129 (CI 95% 0.059-0.285, p-value < 0.001) compared to controls. Surface Cu concentration for all three products was consistent throughout the 12-month period. Electron microscopy (SEM) and Energy-dispersive X-ray Spectroscopy (EDS) cross-sectional analysis showed no change in thickness or dealloying of Cu products, however SEM top-down analysis revealed substantial carbon accumulation on all surfaces. Cu products installed on transit vehicles maintained antimicrobial efficacy and durability after 12 months of use.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10958017PMC
http://dx.doi.org/10.1038/s41598-024-56225-9DOI Listing

Publication Analysis

Top Keywords

three buses
8
colony forming
8
forming units
8
units cfu
8
one-year trial
4
trial evaluating
4
evaluating durability
4
durability antimicrobial
4
antimicrobial efficacy
4
efficacy copper
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!