A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A compact Fourier-transform near-infrared spectrophotometer and chemometrics for characterizing a comprehensive set of seized ecstasy samples. | LitMetric

A compact Fourier-transform near-infrared spectrophotometer and chemometrics for characterizing a comprehensive set of seized ecstasy samples.

Spectrochim Acta A Mol Biomol Spectrosc

Group of Analysis and Education for Sustainability (GAES), Chemistry Department, Federal University of Viçosa (UFV), Viçosa, MG, 36570-900, Brazil. Electronic address:

Published: June 2024

A comprehensive data set of ecstasy samples containing MDMA (N-methyl-3,4-methylenedioxyamphetamine) and MDA (3,4-methylenedioxyamphetamine) seized by the Brazilian Federal Police was characterized using spectral data obtained by a compact, low-cost, near-infrared Fourier-transform based spectrophotometer. Qualitative and quantitative characterization was accomplished using soft independent modeling of class analogy (SIMCA), linear discriminant analysis (LDA) classification, discriminating partial least square (PLS-DA), and regression models based on partial least square (PLS). By applying chemometric analysis, a protocol can be proposed for the in-field screening of seized ecstasy samples. The validation led to an efficiency superior to 96 % for ecstasy classification and estimating total actives, MDMA, and MDA content in the samples with a root mean square error of validation of 4.4, 4.2, and 2.7 % (m/m), respectively. The feasibility and drawbacks of the NIR technology applied to ecstasy characterization and the compromise between false positives and false negatives rate achieved by the classification models are discussed and a new approach to improve the classification robustness was proposed considering the forensic context.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2024.124163DOI Listing

Publication Analysis

Top Keywords

ecstasy samples
12
seized ecstasy
8
partial square
8
ecstasy
5
compact fourier-transform
4
fourier-transform near-infrared
4
near-infrared spectrophotometer
4
spectrophotometer chemometrics
4
chemometrics characterizing
4
characterizing comprehensive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!