A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pancreatic cancer detection with dual-energy CT: diagnostic performance of 40 keV and 70 keV virtual monoenergetic images. | LitMetric

Purpose: To compare the diagnostic performance of 40 keV and 70 keV virtual monoenergetic images (VMIs) generated from dual-energy CT in the detection of pancreatic cancer.

Methods: This retrospective study included patients who underwent pancreatic protocol dual-energy CT from January 2019 to August 2022. Four radiologists (1-11 years of experience), who were blinded to the final diagnosis, independently and randomly interpreted 40 keV and 70 keV VMIs and graded the presence or absence of pancreatic cancer. For each image set (40 keV and 70 keV VMIs), the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated. The diagnostic performance of each image set was compared using generalized estimating equations.

Results: Overall, 137 patients (median age, 71 years; interquartile range, 63-78 years; 77 men) were included. Among them, 62 patients (45%) had pathologically proven pancreatic cancer. The 40 keV VMIs had higher specificity (75% vs. 67%; P < .001), PPV (76% vs. 71%; P < .001), and accuracy (85% vs. 81%; P = .001) than the 70 keV VMIs. On the contrary, 40 keV VMIs had lower sensitivity (96% vs. 98%; P = .02) and NPV (96% vs. 98%; P = .004) than 70 keV VMIs. However, the diagnostic confidence in patients with (P < .001) and without (P = .001) pancreatic cancer was improved in 40 keV VMIs than in 70 keV VMIs.

Conclusions: The 40 keV VMIs showed better diagnostic performance in diagnosing pancreatic cancer than the 70 keV VMIs, along with higher reader confidence.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11547-024-01806-xDOI Listing

Publication Analysis

Top Keywords

pancreatic cancer
12
diagnostic performance
12
performance kev
8
virtual monoenergetic
8
monoenergetic images
8
kev 70 kev
8
included patients
8
70 kev vmis
8
image set
8
pancreatic
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!