Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11599294PMC
http://dx.doi.org/10.1007/s12028-024-01966-8DOI Listing

Publication Analysis

Top Keywords

speaking valve
4
valve nasal
4
nasal airflow
4
airflow tracheostomy
4
tracheostomy weaning
4
weaning case
4
case series
4
speaking
1
nasal
1
airflow
1

Similar Publications

Transcatheter aortic valve implantation complexity score.

Open Heart

January 2025

Department of Cardiology, Leeds General Infirmary, Leeds, UK

Background: Increasing demand for transcatheter aortic valve implantation (TAVI) places greater emphasis on the efficiency of pathways and services. A significant limitation to increasing TAVI capacity is the availability of cardiac catheterisation laboratory time. We have developed a novel complexity scoring system (TAVI ComplEXity; TEX score) which can aid in planning lists with appropriate case selection.

View Article and Find Full Text PDF
Article Synopsis
  • The study examines the outcomes of mitral transcatheter edge-to-edge repair (TEER) performed during off-hours (before 7:30 am, after 5:30 pm, or on weekends/holidays) to see how they compare to procedures done during regular hours.
  • The analysis included 1,177 procedures, with 117 (9.9%) occurring off-hours; off-hours procedures were often urgent and involved higher-risk patients, yet technical success was high in both groups.
  • Although baseline MR severity and functional class improved for both groups, off-hours patients experienced higher rates of deaths and heart failure hospitalizations, with no procedural timing linked to outcomes in matched comparisons, suggesting experienced interventionalists can conduct these procedures safely regardless
View Article and Find Full Text PDF

Outcomes and Impact of Device Iterations in Mitral Valve Transcatheter Edge-to-Edge Repair: The REPAIR Study.

JACC Cardiovasc Interv

November 2024

Department of Cardiology, Heart Center, Faculty of Medicine, University of Cologne, Cologne, Germany. Electronic address:

Background: The PASCAL P10 system for mitral valve transcatheter edge-to-edge repair has undergone iterations, including introduction of the narrower Ace implant and the Precision delivery system.

Objectives: The study sought to evaluate outcomes and the impact of PASCAL mitral valve transcatheter edge-to-edge repair device iterations.

Methods: The REPAIR (REgistry of PAscal for mltral Regurgitation) study is an investigator-initiated, multicenter registry including consecutive patients with mitral regurgitation (MR) treated from 2019 to 2024.

View Article and Find Full Text PDF

Tricuspid valve edge-to-edge repair simulations are highly sensitive to annular boundary conditions.

J Mech Behav Biomed Mater

December 2024

Department of Mechanical Engineering, The University of Texas at Austin, 204 E. Dean Keeton Street, Austin, TX, 78712, USA; Department of Aerospace Engineering & Engineering Mechanics, The University of Texas at Austin, 2617 Wichita Street, Austin, TX, 78712, USA; Department of Biomedical Engineering, The University of Texas at Austin, 107 W. Dean Keeton Street, Austin, TX, 78712, USA; The Oden Institute for Computational Engineering & Sciences, The University of Texas at Austin, 201 E. 24th Street, Austin, TX, 78712, USA. Electronic address:

Transcatheter edge-to-edge repair (TEER) simulations may provide insight into this novel therapeutic technology and help optimize its use. However, because of the relatively short history and technical complexity of TEER simulations, important questions remain unanswered. For example, there is no consensus on how to handle the annular boundary conditions in these simulations.

View Article and Find Full Text PDF

One-year hemodynamic and clinical outcomes in self-expanding valves: Comparison of ACURATE neo2 versus ACURATE neo.

Cardiovasc Revasc Med

December 2024

Department of Cardiology and Catheterization Laboratories, Shonan Kamakura General Hospital, Okamoto 1370-1, Kamakura City, Kanagawa 247-8533, Japan. Electronic address:

Background/purpose: Transcatheter aortic valve replacement (TAVR) with ACURATE neo2 showed better hemodynamic outcomes by mitigating paravalvular leakage (PVL) compared with ACURATE neo, and revealed promising one-year outcomes in single-arm studies. However, studies comparing the hemodynamic and clinical outcomes of the two valves are still scarce. Therefore, this study aimed to compare the one-year hemodynamic and clinical outcomes between the neo2 and neo.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!