AI Article Synopsis

  • Modifier 22 helps surgeons indicate when a procedure is more complex than the standard coding suggests, but there's limited research on how effective it is.
  • The study analyzed 2021 data on 625,316 surgical procedures to understand how often modifier 22 is used and its impact on payment.
  • Results showed that modifier 22 was used in 2.3% to 8.5% of the cases, often leading to higher charges but also increased likelihood of claim denial, resulting in mixed overall payments.

Article Abstract

Importance: Modifier 22 is a mechanism designed for surgeons to identify cases that are more complex than their Current Procedural Terminology code accounts for. However, empirical studies of the use and efficacy of modifier 22 are lacking.

Objective: To assess the use of modifier 22 in common surgical procedures and the association of use with compensation.

Design, Setting, And Participants: This was a cross-sectional analysis of the 2021 Physician/Supplier Procedure Summary Limited Data Set including all Part B carrier and durable medical equipment fee-for-service claims. Claims for 10 common surgical procedures were evaluated, including mastectomy, total hip arthroplasty, total knee arthroplasty, coronary artery bypass grafting, laparoscopic right colectomy, laparoscopic appendectomy, laparoscopic cholecystectomy, kidney transplant, laparoscopic total abdominal hysterectomy and bilateral salpingo-oophorectomy, and lumbar laminectomy. Data were analyzed from August to November 2023.

Main Outcomes And Measures: Rate of modifier 22 use, rate of claim denial, mean charges, mean payment for accepted claims, and mean payment for all claims.

Results: The sample included 625 316 surgical procedures performed in calendar year 2021. The proportion of modifier 22 coding for a procedure ranged from 5725 of 251 521 (2.3%) in total knee arthroplasty to 1566 of 18 459 (8.5%) in laparoscopic total abdominal hysterectomy and bilateral salpingo-oophorectomy. Submitted charges were 11.1% (95% CI, 9.1-13.2) to 22.8% (95% CI, 21.3-24.3) higher for claims with modifier 22, depending on the procedure. Among accepted claims, those with modifier 22 had increased payments ranging from 0.8% (95% CI, 0.7-1.0) to 4.8% (95% CI, 4.5-5.1). However, claims with modifier 22 were more likely to be denied (7.4% vs 4.0%; P < .001). As a result, overall mean payments were mixed, with 4 procedures having lower payments when modifier 22 was appended, 4 procedures having higher payments with modifier 22, and 2 procedures with no difference. The largest increase in mean payment for modifier 22 claims was for kidney transplant with an increased payment of $71.46 (95% CI, 55.32-87.60), which translates to a relative increase of 3.4% (95% CI, 2.9-4.6).

Conclusions And Relevance: The findings in this study suggest that modifier 22 had little to no financial benefit when appended to claims for a diverse panel of surgical procedures. In the current system, surgeons have little reason to request modifier 22, and no mechanisms currently exist for surgeons to recoup payment for difficult operations.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10955341PMC
http://dx.doi.org/10.1001/jamasurg.2024.0048DOI Listing

Publication Analysis

Top Keywords

surgical procedures
12
claims modifier
12
modifier
9
common surgical
8
total knee
8
knee arthroplasty
8
laparoscopic total
8
total abdominal
8
abdominal hysterectomy
8
hysterectomy bilateral
8

Similar Publications

Objective: To compare the 3-year outcomes of the modified minimally invasive Ponto surgery (m-MIPS) to both the original MIPS (o-MIPS) and linear incision technique with soft tissue preservation (LIT-TP) for inserting bone-anchored hearing implants (BAHIs).

Study Design: Prospective study with three patient groups: m-MIPS, o-MIPS, and LIT-TP.

Setting: Tertiary referral center.

View Article and Find Full Text PDF

Detection of Extracochlear Electrodes Using Electrical Field Imaging (EFI).

Otol Neurotol

February 2025

Department of Otolaryngology-Head and Neck Surgery, Mayo Clinic, Rochester, Minnesota.

Objective: To analyze the use of electrical field imaging (EFI) in the detection of extracochlear electrodes in cochlear implants (CI).

Study Design: Retrospective cohort study.

Setting: Tertiary academic medical center.

View Article and Find Full Text PDF

Objective: The aim of this study is to test the feasibility of a custom 3D-printed guide for performing a minimally invasive cochleostomy for cochlear implantation.

Study Design: Prospective performance study.

Setting: Secondary care.

View Article and Find Full Text PDF

Objective: This study aims to evaluate the potential association of perioperative hearing outcomes with frailty by Modified 5-Item Frailty Index (mFI-5).

Design: Retrospective cross-sectional study.

Setting: Single-institutional study conducted at a tertiary care hospital between January 2018 and January 2022.

View Article and Find Full Text PDF

Objective: To investigate the association between postoperative antibiotic prophylaxis and the risk of infections leading to implant explantation or hospitalization, with a follow-up of up to 12 years.

Study Design: Retrospective cohort study.

Setting: Tertiary medical institution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?