AI Article Synopsis

  • Expanded endonasal approaches (EEAs) have shown effectiveness in treating specific issues at the petrous apex (PA), but the complexity of the surrounding anatomy poses challenges.
  • This study investigates the contralateral nasofrontal trephination (CNT) route as an alternative method to enhance access to the PA.
  • Findings reveal that the CNT approach significantly reduces the distance to the PA and improves instrument angles and surgical freedom compared to EEA alone, indicating its potential for better clinical outcomes.

Article Abstract

Background And Objectives: Expanded endonasal approaches (EEAs) have proven safe and effective in treating select petrous apex (PA) pathologies. Angled endoscopes and instruments have expanded indications for such approaches; however, the complex neurovascular anatomy surrounding the petrous region remains a significant challenge. This study evaluates the feasibility, anatomic aspects, and limitations of a contralateral nasofrontal trephination (CNT) route as a complementary corridor improving access to the PA.

Methods: Expanded endonasal and CNT approaches to the PA were carried out bilaterally in 15 cadaveric heads with endovascular latex injections. The distance to the PA, angle between instruments through the 2 approach portals, and surgical freedom were measured and compared.

Results: Three-dimensional DICOM-based modeling and visualization indicate that the CNT route reduces the distance to the target located within the contralateral PA by an average of 3.33 cm (19%) and affords a significant increase in the angle between instruments (15.60°; 54%). Furthermore, the vertical vector of approach is improved by 28.97° yielding a caudal reach advantage of 2 cm. The area of surgical freedom afforded by 3 different approaches (endonasal, endonasal with an endoscope in CNT portal, and endonasal with an instrument in CNT portal) was compared at 4 points: the dural exit point of the 6th cranial nerve, jugular foramen, foramen lacerum, and petroclival fissure. The mean area of surgical freedom provided by both approaches incorporating the CNT corridor was superior to EEA alone at each of the surgical targets ( P = <.001).

Conclusion: The addition of a CNT portal provides an additional avenue to expand on the classical EEA to the PA. This study provides insight into the anatomic nuances and potential clinical benefits of a dual-port approach to the PA.

Download full-text PDF

Source
http://dx.doi.org/10.1227/ons.0000000000001119DOI Listing

Publication Analysis

Top Keywords

surgical freedom
12
contralateral nasofrontal
8
nasofrontal trephination
8
petrous apex
8
expanded endonasal
8
cnt route
8
angle instruments
8
area surgical
8
cnt portal
8
cnt
6

Similar Publications

Development of a single port dual arm robotically steerable endoscope for neurosurgical applications.

Npj Robot

January 2025

Medical Robotics and Automation (RoboMed) Laboratory, Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA.

Single-port surgical robots have gained popularity due to less patient trauma and quicker post-surgery recovery. However, due to limited access provided by a single incision, the miniaturization and maneuverability of these robots still needs to be improved. In this paper, we propose the design of a single-port, dual-arm robotically steerable endoscope containing one steerable major cannula and two steerable minor cannulas.

View Article and Find Full Text PDF

Background: The expanded polytetrafluoroethylene (ePTFE) valved conduit (VC) has been reported for pulmonary valve replacement (PVR). The purpose of this study was to review long-term outcomes of our trileaflet ePTFE VC.

Methods: This multicenter study was performed with institutional review board approval from each institution.

View Article and Find Full Text PDF

In recent years, robotic assistance has become increasingly used and applied in minimally invasive surgeries. A new cooperative surgical robot system that includes a joystick-guided robotic scope holder was developed in this study, and its feasibility for use in minimally invasive abdominal surgery was evaluated in a preclinical setting. The cooperative surgical robot consists of a six-degree-of-freedom collaborative robot arm and a one-degree-of-freedom bidirectional telescopic end-effector specializing in surgical assistance.

View Article and Find Full Text PDF

Background: The long-term comparative results between porcine and pericardial bioprostheses for surgical aortic valve replacement (SAVR) is debated. Scarce information exists concerning direct comparative evaluation among contemporary devices. We compared late and very late results in a single center series (N=3,983 cases).

View Article and Find Full Text PDF

The Role of [F]F-FDG PET/CT for Predicting Histology and Prognosis in Patients with Thymic Lesions.

Mol Diagn Ther

January 2025

Thoracic Surgery and Lung Transplantation, Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, 20122, Milan, Italy.

Objectives: To investigate whether 18F-fluorodeoxyglucose positron emission tomography-computed tomography ([F]F-FDG PET/CT) metabolic parameters were associated with histology and to assess their prognostic role in patients with thymic lesions.

Patients And Methods: In total, 116 patients (49/67 M/F; mean age 59.5 years) who underwent preoperative [F]F-FDG PET/CT and thymectomy from 2012 to 2022 were retrospectively analyzed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!