A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Diverse thermal desorption combined with self-aspirating corona discharge ionization for direct mass spectrometry analysis of complex samples. | LitMetric

The thermal desorption (TD) technique is widely employed in modern mass spectrometry to facilitate the detection of non-volatile analytes. In this study, we developed a compact TD device based on a small resistance wire and coupled it with a self-aspirating corona discharge ionization (CDI) source to conduct direct MS analysis of various liquid and solid samples. Due to its small size and low heat capacity, the temperature of the TD module can be flexibly and rapidly modulated by controlling the power sequence. Multiple heating modes, including pulse heating (PH), isothermal heating, and step heating (SH), are realized and characterized, and then applied for the detection of different real samples. In particular, the PH mode is suitable for the simultaneous detection of multiple components in samples with relatively simple matrices, while the SH mode is capable of component separation. In addition, the sensitivity and quantitative capability of the TD-CDI system for DEP solutions were tested, showing acceptable stability with a relative standard deviation of about 6.7% and a detection limit of 0.088 ng. Overall, the developed TD-CDI system provides a simple, convenient, and versatile tool for direct mass spectrometry analysis of real samples.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d4ay00200hDOI Listing

Publication Analysis

Top Keywords

mass spectrometry
12
thermal desorption
8
self-aspirating corona
8
corona discharge
8
discharge ionization
8
direct mass
8
spectrometry analysis
8
real samples
8
td-cdi system
8
samples
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!