Potential arrhythmic substrate of atrial fibrillation at the left atrial diverticulum.

Nagoya J Med Sci

Department of Cardiovascular Medicine, General Hospital Minamiseikyo Hospital, Nagoya, Japan.

Published: February 2024

Catheter ablation therapy for persistent atrial fibrillation (PeAF) is both difficult and has limited outcomes. The mechanisms underlying the development and persistence of atrial fibrillation (AF) are not fully understood; therefore, ablation strategies are diverse. A 45-year-old man was referred to our hospital for persistent atrial fibrillation to undergo radiofrequency catheter insertion (RFCA). In the first session we conducted pulmonary vein isolation and additional linear ablation, including that of the roof line and posterior inferior line (posterior box lesion) as the stepwise ablation. However, AF was recurred in six months, therefore he was readmitted for second session ablation preoperative 3D computed tomography (CT) scan for drug-refractory PeAF was performed. The additional isolation of the left superior pulmonary vein and potential drivers of AF by mapping wavefront propagation using multipolar catheters by CARTOFINDER (Biosense Webster, Inc, Diamond Bar, CA, USA) was conducted. However, AF did not terminate. Tomography revealed that the left atrial (LA) diverticulum (LAD) was found uniquely. Electrophysiological findings showed focal firing of the myocardial sleeve and LA diverticulum by an approach for defragmented potentials by re-visiting in interval confidence level (ICL) mode included in the electroanatomical mapping system (CARTO 3, Biosense Webster, Inc, Diamond Bar, CA, USA) and the ablation by encircling this site finally made AF terminate. The AF has not recurred for more than 12 months without the use of antiarrhythmic drugs. This case report suggests that additional ablation around substrates in LAD may be effective for treating refractory AF.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10945233PMC
http://dx.doi.org/10.18999/nagjms.86.1.142DOI Listing

Publication Analysis

Top Keywords

atrial fibrillation
16
left atrial
8
atrial diverticulum
8
persistent atrial
8
pulmonary vein
8
recurred months
8
biosense webster
8
webster diamond
8
diamond bar
8
bar usa
8

Similar Publications

Purpose: This study examines the link between high occupational noise exposure and atrial fibrillation (AF), given the limited existing evidence.

Methods: We conducted a cross-sectional study among participants from a large heavy industry enterprise in China. High noise exposure was defined as an equivalent A-weighted sound level (LAeq, 8 h) of ≥ 80 dB(A) during an 8 h workday.

View Article and Find Full Text PDF

Introduction: Atrial fibrillation (AF) is the most prevalent form of cardiac arrhythmia worldwide. Early diagnosis and treatment are essential, emphasizing the need to develop novel biomarkers. Lipoprotein(a) [Lp(a)] has recently been widely investigated as a potential risk factor for various cardiovascular conditions, including AF.

View Article and Find Full Text PDF

Comparative Evaluation of Consumer Wearable Devices for Atrial Fibrillation Detection: Validation Study.

JMIR Form Res

January 2025

Limburg Clinical Research Center/Mobile Health Unit, Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium.

Background: Consumer-oriented wearable devices (CWDs) such as smartphones and smartwatches have gained prominence for their ability to detect atrial fibrillation (AF) through proprietary algorithms using electrocardiography or photoplethysmography (PPG)-based digital recordings. Despite numerous individual validation studies, a direct comparison of interdevice performance is lacking.

Objective: This study aimed to evaluate and compare the ability of CWDs to distinguish between sinus rhythm and AF.

View Article and Find Full Text PDF

Background: Excessive supraventricular ectopic activity (ESVEA) is regarded as a risk marker for later atrial fibrillation (AF) detection.

Methods And Results: The investigator-initiated, prospective, open, multicenter MonDAFIS (Impact of Standardized Monitoring for Detection of Atrial Fibrillation in Ischemic Stroke) study randomized 3465 patients with acute ischemic stroke without known AF 1:1 to usual diagnostic procedures for AF detection or additive Holter monitoring in hospital for up to 7 days, analyzed in a core laboratory. Secondary study objectives include the comparison of recurrent stroke, myocardial infarction, major bleeding, and all-cause death within 24 months in patients with ESVEA (defined as ectopic supraventricular beats ≥480/day or atrial runs of 10-29 seconds or both) versus patients with newly diagnosed AF versus patients without ESVEA or AF (non-ESVEA/AF), randomized to the intervention group.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!