A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Hemodynamic Monitoring Using a Pulmonary Artery Catheter Versus the Vigileo/FloTrac System during Elective Cardiac Surgery Based on Real-world Data in Japan. | LitMetric

Background: The controversy concerning the benefits of pulmonary artery catheter (PAC)-based hemodynamic monitoring in cardiac surgeries has not been adequately addressed. This study aims to compare the all-cause mortality between the PAC with venous oxygen saturation monitoring and the Vigileo/FloTrac (FloTrac) system with central venous oxygen saturation monitoring in cardiac surgeries.

Methods: This nationwide retrospective study includes adult patients who underwent elective cardiac surgeries between April 2010 and October 2014, based on the Japanese health insurance claims database. The main outcome was 30-day all-cause mortality. Propensity scores (PS) were used to adjust for the confounding factors. Treatment effects were estimated using multivariable logistic regression analysis, including PS.

Results: A total of 5,838 patients were included in this study. The crude 30-day mortality rates were 2.4% (8/334) and 1.7% (96/5,504) in the FloTrac and PAC groups, respectively. After PS matching, the ORs for 30-day all-cause mortality, in-hospital mortality after PAC placement (vs. FloTrac) were 0.36 (95% CI: 0.05-2.37; p = 0.28) and 0.59 (95% CI: 0.16-2.20; p = 0.43), respectively. The amount of dobutamine was larger in the PAC group (281 ± 31 mg vs 155 ± 19 mg; p < 0.001). There were no significant differences in the amounts of other inotropes, the volume of fluids, or blood transfusions.

Conclusions: The association between PAC (with venous oxygen saturation monitoring) and mortality in patients who underwent elective cardiac surgeries was unclear compared to FloTrac (with central venous oxygen saturation monitoring). Additional investigation is needed to evaluate the benefits of PAC-specific hemodynamic parameters in this population.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10760491PMC
http://dx.doi.org/10.37737/ace.22011DOI Listing

Publication Analysis

Top Keywords

venous oxygen
16
oxygen saturation
16
saturation monitoring
16
elective cardiac
12
cardiac surgeries
12
all-cause mortality
12
hemodynamic monitoring
8
pulmonary artery
8
artery catheter
8
monitoring cardiac
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!