A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel epoxy-bPBD-BisMSB composite plastic scintillator for alpha, beta and gamma radiation detection. | LitMetric

Novel epoxy-bPBD-BisMSB composite plastic scintillator for alpha, beta and gamma radiation detection.

Sci Rep

Nuclear Radiation Management and Application Division, Defence Laboratory (DRDO), Jodhpur, 342011, India.

Published: March 2024

A composite plastic scintillator is prepared by uniform dispersion of organic fluorophores 2-(4-Biphenylyl)-5-(4-tert-butylphenyl)-1,3,4-oxadiazole (b-PBD) and 1,4-bis(2-methylstyryl) benzene (Bis-MSB) in epoxy resin followed by curing at room temperature. The developed scintillator is strong blue emitter (425 nm), confirmed by 365 nm UV excited Photo luminescence and beta particle (Sr-Y) excited Radio-luminescence characterizations. The developed scintillator is highly transparent (~ 70%) to emitted light wavelength. Moreover, the scintillator's blue emission is appropriate for photomultiplier tube (PMT) based scintillation measurement due to its maximum peak spectral response in blue region. Alpha, beta and gamma radiation detection were performed on PMT coupled scintillators of sizes Ø50 mm × 1 mm, Ø50 mm × 5 mm and Ø50 mm × 25 mm respectively. Pulse height spectra were recorded using 1 k Multichannel analyser (MCA) using various reference radiation sources. All scintillators demonstrated promising response to the respective radiations. Absolute detection efficiency of alpha scintillator is obtained as 32% (Am), 86% of that of standard plastic scintillator EJ-212. Beta endpoint energy and gamma Compton edges showed linear variation w.r.t. corresponding channel numbers. Detection efficiency of beta and gamma scintillator is found to be 35.7% (Sr-Y) and 6.7% (Cs) respectively. The developed scintillator has potential to be used for radioactivity contamination & gamma dose rate measurement applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10951283PMC
http://dx.doi.org/10.1038/s41598-023-45501-9DOI Listing

Publication Analysis

Top Keywords

plastic scintillator
12
beta gamma
12
developed scintillator
12
composite plastic
8
scintillator
8
alpha beta
8
gamma radiation
8
radiation detection
8
detection efficiency
8
beta
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!