Background Successful endodontic treatment relies on the effective removal of debris and the prevention of smear layer formation within the root canals. The choice of nickel-titanium (Ni-Ti) rotary instrument systems can significantly impact these outcomes. Aim This study aims to evaluate and compare the debris and smear layer formation in root canals of extracted mandibular second premolar teeth following instrumentation with the ProTaper Universal (Dentsply Sirona, Charlotte, NC) (Group II), Twisted File (Kerr Endodontics, Gilbert, AZ) (Group III), and XP Endo (FKG Dentaire, La Chaux-de-Fonds, Switzerland) (Group IV) Ni-Ti rotary instrument systems. Methods In this in vitro study, 60 extracted mandibular second premolar teeth were randomly divided into four groups, each containing 15 teeth. Group I served as the control with no instrumentation. Groups II, III, and IV were instrumented with the ProTaper Universal rotary file, the Twisted File, and the XP Endo file systems, respectively. Debris and smear layer formation were evaluated through scanning electron microscopy (SEM), and photomicrographs were scored using a standardized index. Results Group II (ProTaper) exhibited the highest mean debris and smear layer scores, with values of 3.50 and 2.70, respectively. Group IV (XP Endo) demonstrated the least debris and smear layer formation, with mean scores of 2.65 and 2.08, respectively. Statistical analysis confirmed significant differences among the groups for both debris and smear layer formation. Conclusion The results highlight the practical importance of selecting appropriate Ni-Ti rotary instrument systems to minimize debris and smear layer formation during endodontic procedures. The XP Endo file system showed promise as a favorable choice in this regard, but further clinical research is needed to validate these findings.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10944652PMC
http://dx.doi.org/10.7759/cureus.54310DOI Listing

Publication Analysis

Top Keywords

smear layer
32
debris smear
28
layer formation
28
ni-ti rotary
16
rotary instrument
16
instrument systems
16
nickel-titanium ni-ti
8
debris
8
systems debris
8
smear
8

Similar Publications

Background: Disinfection of the root canal system is a challenge to all clinicians, calcium hydroxide Ca(OH) one of the most popular intracanal medications used for this purpose, has some unwanted effects on dentine. This study aimed to investigate the antibiofilm effect of Nanochitosan (CSNPs) and Calcium hydroxide Ca(OH) intra canal medications and their effect on the microhardness and chemical structure of radicular dentine.

Methodology: A total of 52 extracted human mandibular premolars were used.

View Article and Find Full Text PDF

Aim: To investigate the effectiveness of unconventional post space disinfection techniques, specifically Er:YAG laser, Temoporfin, and Carbon Nanoparticles (CNPs), in improving Martens hardness (MH), eliminating the smear layer (SL), and enhancing the push-out bond strength (PBS) of glass fiber posts in canal dentin.

Methods: An in vitro study was conducted utilizing 80 single-rooted extracted human teeth, which were decoronated and subjected to standardized root canal preparation. The teeth were equally distributed into four experimental groups: Group 1 (NaOCl + EDTA), Group 2 (Er: YAG laser + EDTA), Group 3 (Temoporfin + EDTA), and Group 4 (CNPs + EDTA).

View Article and Find Full Text PDF

Evaluation of bacterial biofilm, smear layer, and debris removal efficacy of a hydro-dynamic cavitation system with physiological saline using a new ex vivo model: a CLSM and SEM study.

BMC Oral Health

January 2025

Division of Endodontics, Department of Oral Biological and Medical Sciences, Faculty of Dentistry, University of British Columbia, 2199 Wesbrook Mall, Vancouver, British Columbia, V6T 1Z3, Canada.

Introduction: To evaluate the bacterial biofilm, smear layer and debris removal efficacy of a hydro-dynamic cavitation system with physiological saline using a new ex vivo model.

Methods: Seventy-five dentin discs were prepared from fifty-four extracted teeth. Seventy-five artificial root sockets were prepared.

View Article and Find Full Text PDF

Objective: To assess the state of endodontic practices and identify factors influencing the use of modern endodontic techniques among dental practitioners in Croatia.

Materials And Methods: A questionnaire was distributed to all dental offices in Croatia, yielding 819 responses (27% response rate). Data were descriptively analyzed and statistically modeled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!