A PHP Error was encountered

Severity: Warning

Message: fopen(/var/lib/php/sessions/ci_sessionlog8d32ptr2dfphqk0742em26j6ebggl): Failed to open stream: No space left on device

Filename: drivers/Session_files_driver.php

Line Number: 177

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Failed to read session data: user (path: /var/lib/php/sessions)

Filename: Session/Session.php

Line Number: 137

Backtrace:

File: /var/www/html/index.php
Line: 316
Function: require_once

Plug-and-play DPC-based quantitative phase microscope. | LitMetric

Point-of-care testing (POCT) plays an increasingly important role in biomedical research and health care. Quantitative phase microscopes (QPMs) with good contrast, no invasion, no labeling, high speed and automation could be effectively applied for POCT. However, most QPMs are fixed on the optical platform with bulky size, lack of timeliness, which remained challenging in POCT solutions. In this paper, we proposed a plug-and-play QPM with multimode imaging based on the quantitative differential phase contrast (qDPC) method. The system employs a programmable LED array as the light source and uses the GPU to accelerate the calculation, which can realize multi-contrast imaging with six modes. Accurate phase measurement and real-time phase imaging are implemented by the proposed qDPC algorithms for quantitative phase targets and biomedical samples. A 3D electric control platform is designed for mechanical control of field of view and focusing without manual operations. The experimental results verify the robustness and high performance of the setup. Even a rookie could finish the POCT scheme for biomedical applications at the scene using the QPM with a compact size of 140 × 165 × 250 mm.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10942692PMC
http://dx.doi.org/10.1364/BOE.514887DOI Listing

Publication Analysis

Top Keywords

quantitative phase
12
phase
6
plug-and-play dpc-based
4
quantitative
4
dpc-based quantitative
4
phase microscope
4
microscope point-of-care
4
point-of-care testing
4
poct
4
testing poct
4

Similar Publications

Transcription Factor EB (TFEB) controls lysosomal biogenesis and autophagy in response to nutritional status and other stress factors. Although its regulation by nuclear translocation is known to involve a complex network of well-studied regulatory processes, the precise contribution of each of these mechanisms is unclear. Using microfluidics technology and real-time imaging coupled with mathematical modelling, we explored the dynamic regulation of TFEB under different conditions.

View Article and Find Full Text PDF

Physicians evaluate a patient's respiratory health during a physical examination by visual assessment of the work of breathing (WoB) to determine respiratory stability, and by detecting abnormal lung sounds via lung auscultation using a stethoscope to identify common pathological lung diseases, such as chronic obstructive pulmonary disease (COPD) and pneumonia. Since these assessment methods are subjective, a low-profile device used for an accurate and quantitative monitoring approach could provide valuable preemptive insights into respiratory health, proving to be clinically beneficial. To achieve this goal, we have developed a miniature patch consisting of a sensitive wideband multi-axis seismometer that can be placed on the anatomical areas of a patient's lungs to enable an effective quantification of a patient's WoB and lung sounds.

View Article and Find Full Text PDF

Methods for measuring environmental toxicity and identifying chemical toxicity drivers using non-targeted analysis (NTA) were reviewed in this systematic quantitative literature review. Effect-directed analysis (EDA) was used to assess sample toxicity and prioritise NTA sample analysis. The most common bioassays performed were estrogen, androgen and aryl hydrocarbon receptor assays, with many studies using test batteries.

View Article and Find Full Text PDF

Background: Monitoring child development requires not only the determination of developmental milestones but also surveillance and continuous monitoring, hence the importance of having valid and reliable evaluation instruments. This research aimed to cross-culturally adapt the Child Development Evaluation (CDE) test for Colombia and determine its validity and reliability.

Methods: The cross-cultural adaptation process was conducted in four phases: I.

View Article and Find Full Text PDF

β-3 adrenoceptor (AR) counteracts the β-1 and β-2 ARs and rescues the effects of excessive catecholamines. To test the hypothesis that a β-3 AR agonist (mirabegron) can reverse the effects of isoproterenol (ISO) on ventricular fibrillation (VF), we performed optical mapping studies in six male and six female Langendorff perfused rabbit hearts at baseline and after sequential administration of ISO (100 nm), mirabegron (1000 nm), apamin (100 nm) and washout (Study I). An additional six male and six female hearts were studied with mirabegron doses ranging between 250 and 1000 nm without ISO (Study II).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!