A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Adjusting and validating a procedure for parenteral anaesthesia in neonatal mice. | LitMetric

For neonatal pups, parenteral anaesthesia is said to be not reliable as low doses induce no anaesthesia whereas high doses render high mortality rates. In this work we have adapted parenteral anaesthesia procedures approved for pups >7 days of age, to anaesthetize neonatal animals (postnatal days 3-4; P3-P4) for keeping them immobile for a long period. In our first experiment we analysed the behaviour of P3-P4 mouse pups for 70 min after intraperitoneal administration of low (37.5/3.75 mg/kg) or high (50/5) doses of a ketamine/xylazine anaesthetic mixture, both in the low range as compared with dosages employed in adults. Pups became immobile in ≈7 min and remained immobile for ≈45 min, irrespective of the age and dose of anaesthesia, younger pups (P3) being apparently more sensitive to the dosage. In the second experiment, we studied the response of P3 pups to mildly nociceptive stimulations, performed with a 4.0 g von Frey filament applied to the dorsal aspect of their paws. These stimuli elicited reaction in 100% of the cases in non-anaesthetized pups. The results indicate that the high dose significantly reduced responses as compared with the low dose of anaesthesia. With the low dose, <40% of the pups were unresponsive to nociceptive stimulation, whereas the high dose resulted in 50-60% of the animals not responding. Mortality was low irrespective of age or dose, suggesting that doses can be further increased if needed for invasive experimental procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1177/00236772231219821DOI Listing

Publication Analysis

Top Keywords

parenteral anaesthesia
12
dose anaesthesia
8
low dose
8
pups
7
anaesthesia
6
low
5
adjusting validating
4
validating procedure
4
procedure parenteral
4
anaesthesia neonatal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!