The use of mobile head CT scanners in the neurointensive care unit (NICU) saves time for patients and NICU staff and can reduce transport-related mishaps, but the reduced image quality of previous mobile scanners has prevented their widespread clinical use. This study compares the image quality of SOMATOM On.Site (Siemens Healthineers, Erlangen, Germany), a state-of-the-art mobile head CT scanner, and a conventional 64-slice stationary CT scanner. The study included 40 patients who underwent head scans with both mobile and stationary scanners. Gray and white matter signal and noise were measured at predefined locations on axial slices, and signal-to-noise ratios (SNRs) and contrast-to-noise ratios (CNRs) were calculated. Artifacts below the cranial calvaria and in the posterior fossa were also measured. In addition, image quality was subjectively assessed by two radiologists in terms of corticomedullary differentiation, subcalvarial space, skull artifacts, and image noise. Quantitative measurements showed significantly higher image quality of the stationary CT scanner in terms of noise, SNR and CNR of gray and white matter. Artifacts measured in the posterior fossa were higher with the mobile CT scanner, but subcalvarial artifacts were comparable. Subjective image quality was rated similarly by two radiologists for both scanners in all domains except image noise, which was better for stationary CT scans. The image quality of the SOMATOM On.Site for brain scans is inferior to that of the conventional stationary scanner, but appears to be adequate for daily use in a clinical setting based on subjective ratings.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10944493 | PMC |
http://dx.doi.org/10.1038/s41598-024-56089-z | DOI Listing |
Environ Monit Assess
January 2025
School of Mathematical Sciences, Universiti Sains Malaysia, 11800 USM, Penang, Malaysia.
This study investigates the effectiveness and efficiency of two topological data analysis (TDA) techniques, the conventional Mapper (CM) and its variant version, the Ball Mapper (BM), in analyzing the behavior of six major air pollutants (NO, PM, PM, O, CO, and SO) across 60 air quality monitoring stations in Malaysia. Topological graphs produced by CM and BM reveal redundant monitoring stations and geographical relationships corresponding to air pollutant behavior, providing better visualization than traditional hierarchical clustering. Additionally, a comparative analysis of topological graph structures was conducted using node degree distribution, topological graph indices, and Dynamic Time Warping (DTW) to evaluate the sensitivity and performance of these TDA techniques.
View Article and Find Full Text PDFPhys Eng Sci Med
January 2025
Physics Department, Instituto Zunino, Obispo Oro 423, X5000BFI, Córdoba, Argentina.
Treatment Planning Systems (TPS) offer algorithms for distortion correction (DC) of Magnetic Resonance (MR) images, whose performances demand proper evaluation. This work develops a procedure using a virtual phantom to quantitatively assess a TPS DC algorithm. Variations of the digital Brainweb MR study were created by introducing known distortions and Control Points (CPs).
View Article and Find Full Text PDFRev Med Chil
June 2024
Departamento de endocrinología, Hospital Clínico San Borja Arriarán, Santiago, Chile.
Multiple endocrine neoplasia type 1 (MEN1) is a rare autosomal dominant disease with an estimated prevalence of 2 per 100,000. This disease is caused by a mutation in the tumor suppressor gene MEN1, which is located on chromosome 11 and codifies the menin protein. It is characterized by a predisposition of parathyroids, enteropancreatic, and anterior pituitary tumors, affecting the quality of life and lifespan of those who have the disease.
View Article and Find Full Text PDFNano Lett
January 2025
Hangzhou Institute of Technology, Xidian University, Hangzhou 311200, China.
GaO Schottky photodiodes are being actively explored for solar-blind ultraviolet (SBUV) detection, owing to the fast photoresponse and easy fabrication. However, their performance, limited by the Schottky contact, mostly underperforms the expectations. Herein, a Ni/β-GaO vertical Schottky barrier diode (SBD) with an ultrathin anode electrode is demonstrated.
View Article and Find Full Text PDFClin Spine Surg
January 2025
Department of Orthopedic Surgery, NYU Langone Health, New York, NY.
Study Design: Retrospective cohort study.
Objective: To develop parameter thresholds obtainable from cervical radiographs that correlate with concomitant thoracolumbar malalignment.
Summary Of Background Data: T1 slope (T1S) is typically discussed in the context of cervical deformity and correlated with health-related quality of life outcomes.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!