A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous determination of bromoxynil and MCPA in commercial samples and raw materials using reversed phase high performance liquid chromatography. | LitMetric

This study encompasses a quick, efficient, repeatable and reproducible analytical method for simultaneous determination of Bromoxynil (3, 5-Dibromo-4-hydroxybenzonitrile) and MCPA (2-methyl-4-chlorophenoxyacetic acid) using RP-HPLC with UV-Detector. Bromoxynil + MCPA is one of the most selective post emergent herbicide formulations for the control of important broad leaf weeds infesting small grains (wheat, barley, oats, rye), conservation reserve program areas and grass grown for seed. Optimum weed control is achieved when Bromoxynil + MCPA is applied to actively growing weed seedlings. So, a simple, repeatable, reproducible and efficient simultaneous analytical method was developed for Bromoxynil + MCPA. The developed method was applied for the detection and quantitation of these pesticides in formulations and raw materials with excellent recoveries. It was validated according to ICH Guidelines with excellent linearity R = 0.992 for Bromoxynil and 0.998 for MCPA. For Bromoxynil, LOD = 1.57 mg/L and LOQ = 5.22 mg/L while for MCPA the LOD = 1.08 mg/L and LOQ = 3.62 mg/L was found. The proposed method has shown high precision (RSD %) 0.06% and 0.11% for Bromoxynil and MCPA respectively while the trueness has been calculated in terms of recovery percentage obtained as "mean value of Bromoxynil 99.53% and MCPA 100.10%" which is excellent under optimized conditions. For repeatability and reproducibility, five replicate readings of standard and sample were taken and had found within acceptable limits of relative standard deviation (RSD ≤  ± 2%). Finally, the robustness of the developed method was determined by changing flow rate and mobile phase ratios that has found within the permissible limits (% RSD NMT 1.5). So, the proposed analytical method has found to be more precise, valid and accurate at commercial scale.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10943769PMC
http://dx.doi.org/10.1186/s13065-024-01154-xDOI Listing

Publication Analysis

Top Keywords

analytical method
12
simultaneous determination
8
determination bromoxynil
8
bromoxynil mcpa
8
raw materials
8
repeatable reproducible
8
developed method
8
bromoxynil
6
mcpa
6
method
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!