Statement Of Problem: New denture base acrylic resins have been introduced that are specifically formulated for microwave polymerization. Microwave polymerization is a time-efficient procedure, but few studies have evaluated how these new acrylic resin formulations compare with conventionally processed acrylic resins.
Purpose: The purpose of this in vitro study was to compare the stiffness and strength of denture base acrylic resins formulated for microwave polymerization with conventionally processed acrylic resin.
Material And Methods: Rectangular beams were fabricated from 2 microwave-polymerized denture base acrylic resins, microwave-specific resin (Nature-Cryl MC), resin with the option of microwave polymerization (Diamond D), and a conventionally processed resin as a control (Lucitone 199). Specimens (n=10) were stored in water for 1 week and subjected to a 3-point bend test to determine the flexural modulus (stiffness) and flexural strength before (initial properties) or after 120 000 load cycles. The load cycles, conducted between 5 and 25 N at 2 Hz, simulated 6 months of mastication. Data were analyzed by using 2-way ANOVA, followed by pairwise comparisons (α=.05).
Results: The initial flexural modulus (mean ±standard deviation) was conventionally processed resin, 2.65 ±0.33 GPa; microwave-specific resin, 3.01 ±0.20 GPa; and microwave-option resin, 2.63 ±0.04 GPa. After load cycling, the mean flexural modulus was conventionally processed resin, 2.34 ±0.32 GPa; microwave-specific resin, 2.69 ±0.20 GPa; and microwave-option resin, 1.96 ±0.11 GPa. The initial flexural strength was conventionally processed resin, 77.6 ±11.0 MPa; microwave-specific resin, 83.6 ±3.5 MPa; and microwave-option resin, 78.9 ±2.6 MPa. After load cycling, the mean flexural strength was conventionally processed resin, 68.7 ±9.0 MPa; microwave-specific resin, 73.3 ±3.3 MPa; and microwave-option resin, 65.5 ±3.5 MPa. Resin and loading state significantly affected the stiffness and strength (P<.01); the interaction resin×state was not significant (P≥.558).
Conclusions: Microwave-polymerized denture base acrylic resins were comparable in stiffness and strength with conventionally processed acrylic resin. All acrylic resins decreased in stiffness and strength after load cycling. The microwave-specific resin was significantly stiffer and stronger than the other denture base acrylic resins, initially and after 120 000 load cycles.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2024.02.023 | DOI Listing |
Sensors (Basel)
December 2024
V.I. Il'ichev Pacific Oceanological Institute FEB RAS, 690041 Vladivostok, Russia.
The paper describes a planetary laser interferometric seismoacoustic observatory consisting of six stationary unequal arm laser strainmeters. Based on the triangulation method, the fundamentals of direction finding of various infrasound disturbances at any planetary distance have been developed. The authors show that in addition to determining locations of the occurrence of the recorded disturbance, using data from spatially separated laser strainmeters, it is possible to determine the nature of these signals' divergence and, also, the loss of their energy in the propagation medium.
View Article and Find Full Text PDFFoods
December 2024
Division of Data, Statistics and Risk Assessment, Austrian Agency for Health and Food Safety AGES, 1220 Vienna, Austria.
Plant-derived foods are potential vehicles for microbial antibiotic resistance genes (ARGs), which can be transferred to the human microbiome if consumed raw or minimally processed. The aim of this study was to determine the prevalence and the amount of clinically relevant ARGs and mobile genetic elements (MGEs) in differently processed smoothies (freshly prepared, cold-pressed, pasteurized and high-pressure processed) and fresh produce samples (organically and conventionally cultivated) to assess potential health hazards associated with their consumption. The MGE and the class 1 integron-integrase gene were detected by probe-based qPCR in concentrations up to 10 copies/mL in all smoothies, lettuce, carrots and a single tomato sample.
View Article and Find Full Text PDFJ Prosthet Dent
January 2025
Head and Neck Surgeon and Head, Verwelius 3D Lab, Department of Head and Neck Oncology and Surgery, Netherlands Cancer Institute, Amsterdam, The Netherlands.
Statement Of Problem: A nasal prosthesis may compensate for a partial or complete defect of the nose associated with trauma or amputation. However, the design and production is time-consuming, expensive, and expertize-dependent. Computer-generated prosthesis models and 3D printing can optimize the process.
View Article and Find Full Text PDFWorking memory (WM) is an evolving concept. Our understanding of the neural functions that support WM develops iteratively alongside the approaches used to study it, and both can be profoundly shaped by available tools and prevailing theoretical paradigms. Here, the organizers of the 2024 Working Memory Symposium-inspired by this year's meeting-highlight current trends and looming questions in WM research.
View Article and Find Full Text PDFInt J Clin Pediatr Dent
November 2024
Private Practitioner, Bengaluru, Karnataka, India.
Aim: To compare the microleakage in class V cavities restored with Activa Bioactive Restorative, Activa Pronto, and nanohybrid composite.
Materials And Methods: Standardized class V cavity preparations (mesiodistal: 3 mm; occlusocervical: 2 mm; axial depth: 1 mm) were made on the buccal surface of 60 extracted intact maxillary premolar teeth. The preparations were divided into three experimental groups ( = 20) depending on the restorative material used.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!