Purpose Of Review: The field of corneal biomechanics has rapidly progressed in recent years, reflecting technological advances and an increased understanding of the clinical significance of measuring these properties. This review will evaluate in-vivo biomechanical properties obtained by current technologies and compare them regarding their relevance to established biomechanical properties obtained by gold-standard ex-vivo techniques normally conducted on elastic materials.

Recent Findings: Several new technologies have appeared in recent years, including vibrational optical coherence tomography (VOCT) and the corneal indentation device (CID). These techniques provide promising new opportunities for minimally invasive and accurate measurements of corneal viscoelastic properties.

Summary: Alterations in corneal biomechanics are known to occur in several corneal degenerative diseases and after refractive surgical procedures. The measurement of corneal biomechanical properties has the capability to diagnose early disease and monitor corneal disease progression. Several new technologies have emerged in recent years, allowing for more accurate and less invasive measurements of corneal biomechanical properties, most notably the elastic modulus.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICU.0000000000001032DOI Listing

Publication Analysis

Top Keywords

biomechanical properties
16
corneal
8
corneal biomechanics
8
measurements corneal
8
corneal biomechanical
8
properties
5
forays measurement
4
measurement ocular
4
ocular biomechanics
4
biomechanics purpose
4

Similar Publications

Recent studies have attempted to characterize the layer-specific mechanical and microstructural properties of the aortic tissues in either normal or pathological state to understand its structural-mechanical property relationships. However, layer-specific tissue mechanics and compositions of normal and dissected ascending aortas have not been thoroughly compared with a statistical conclusion obtained. Eighteen ascending aortic specimens were harvested from 13 patients with type A aortic dissection and 5 donors without aortic diseases, with each specimen further excised to obtain three tissue samples including an intact wall, an intima-media layer and an adventitia layer.

View Article and Find Full Text PDF

Myoelectric biofeedback (EMG-BF) is a widely recognized and effective method for treating movement disorders caused by impaired nerve function. However, existing EMG-feedback devices are almost entirely located in large medical centers, which greatly limits patient accessibility. To address this critical limitation, there is an urgent need to develop a portable, cost-effective, and real-time monitoring device that can transcend the existing barriers to the treatment of EMG-BF.

View Article and Find Full Text PDF

Bone and Nerve Response to Sciatic Compression Neuropathy in a Rabbit Model.

J Orthop Res

January 2025

Department of Orthopaedic Surgery, Montefiore Einstein, Bronx, New York, USA.

Compression neuropathy is a prevalent medical condition, including common types such as carpal tunnel syndrome, cubital tunnel syndrome, sciatica, and many others. While the neurological consequences are well understood, the effects on bone properties and the potential downstream impact on fracture risk remain less clear. This study aimed to assess the influence of compressive neuropathy on bone properties using a rabbit model of sciatic nerve compression.

View Article and Find Full Text PDF

Before patients begin out-of-bed exercises following internal fixation surgery for acetabular fractures, turning over in bed serves as a crucial intervention to mitigate complications associated with prolonged bed rest. However, data on the safety of this maneuver post-surgery are limited, and the biomechanical evidence remains unclear. This study aims to introduce a novel loading protocol designed to preliminarily simulate the action of turning over in bed and to compare the biomechanical properties of two fixation methods for acetabular fractures under this new protocol.

View Article and Find Full Text PDF

The absence of a clear consensus on the definition and significance of fascia and the indiscriminate use of the term throughout the clinical and scientific literature has led to skepticism regarding its importance in the human body. To address this challenge, we propose that: (1) fasciae, and the fascial interstitia within them, constitute an anatomical system, defined as a layered body-wide multiscale network of connective tissue that allows tensional loading and shearing mobility along its interfaces; (2) the fascial system comprises four anatomical organs: the superficial fascia, musculoskeletal (deep) fascia, visceral fascia, and neural fascia; (3) these organs are further composed of anatomical structures, some of which are eponymous; (4) all these fascial organs and their structural components contain variable combinations and arrangements of the four classically defined tissues: epithelial, connective, muscle, and neural; (5) the overarching functions of the fascial system arise from the contrasting biomechanical properties of the two basic types of layers distributed throughout the system: one predominantly collagenous and relatively stiff, the other rich in hyaluronic acid and viscous, allowing for the free flow of fluid; (6) the topographical organization of these layers in different locations is related to local variations in function (e.g.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!