Background: Anastomotic leak remains a dreaded complication in colorectal surgery. Identifying optimal techniques that minimize its incidence is an active area of investigation. The aim of this experimental study was to evaluate the effect of commonly used hemostatic products on the integrity of colonic anastomoses.
Methods: Male Wistar rats were randomized into 4 groups. In the control group (A), the anastomosis was performed using the standard hand-sewn technique in the ascending colon. In group B the hand-sewn technique was reinforced with a collagen-fibrinogen patch, in group C with fibrin glue, and in group D with a polyethylene glycol (PEG)-coated oxidized cellulose patch. On the 7 postoperative day, anastomotic bursting pressure measurements were obtained. A specimen surrounding the anastomosis was retrieved for histopathologic evaluation.
Results: Of the 19 rats, 17 survived and 15 were included in the analysis (5 in each of groups A, B and C). Testing in group D was discontinued following adverse events in the preliminary experiments. The mean bursting pressure of the anastomosis was significantly higher in the control group (A: 221±19.41 mmHg, B: 151±14.42 mmHg, and C: 112±13.57 mmHg; P=0.001). Anastomotic healing parameters were not different between groups.
Conclusions: Although experimental data support the use of sealants in defective anastomoses, in this study the reinforcement of colonic anastomosis with fibrin or oxidized cellulose-PEG sealants did not improve either bursting pressure values or anastomotic healing. More data from robust anastomoses of animals and humans are needed before sealing becomes common clinical practice in colorectal surgery.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10927628 | PMC |
http://dx.doi.org/10.20524/aog.2024.0859 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!