A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Atrial Functional Substrates for the Prediction of Atrial Fibrillation Recurrence After Pulmonary Vein Isolation. | LitMetric

Low-voltage areas have been used as atrial structural substrates in estimating fibrotic degeneration in patients with atrial fibrillation (AF). The high-resolution maps obtained by recently developed mapping catheters allow the visualization of several functional abnormalities. We investigated the association between left atrial (LA) functional abnormal findings on a high-resolution substrate map and AF recurrence in patients who underwent pulmonary vein isolation without any additional LA substrate ablation. This observational study included 100 consecutive patients who underwent second ablation for AF (paroxysmal, 48%; persistent, 52%). Patients with extra-pulmonary-vein LA substrate ablation during the initial and second ablation were excluded. LA mapping was performed using a 64-pole mini-basket catheter on the RHYTHMIA mapping system (Boston Scientific, Marlborough [Cambridge] Massachusetts). Patients were followed for 2 years. AF recurrence developed in 39 (39%) patients. On the high-resolution substrate map, AF recurrence was associated with the presence of the following findings: low-voltage areas (<1.0 mV, >5 cm; hazard ratio [HR] = 2.53; 95% confidence interval [CI] = 1.30 to 4.93; p <0.006), fractionated-electrogram areas (≥5 peaks, >5 cm; HR = 2.15, 95% CI = 1.10 to 4.19; p = 0.025), LA conduction time of >130 ms (HR = 3.11, 95% CI = 1.65 to 5.88, p <0.0001), deceleration zone (≥5 isochrones/cm; HR = 1.97, 95% CI = 1.04 to 3.37, p = 0.039), and multiple septal break-out points (HR = 3.27, 95% CI = 1.50 to 7.16, p = 0.003). Accumulation of these risk factors increased AF recurrence in a stepwise manner, with an HR = 1.90, 95% CI = 1.44 to 2.52, p <0.00001 for each additional risk factor. In conclusion, a high-resolution map revealed new LA functional substrates associated with AF recurrence. Implementation of functional substrates may improve the prediction of AF recurrence after ablation, and possibly aid the development of tailored AF ablation strategies.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2024.02.027DOI Listing

Publication Analysis

Top Keywords

atrial functional
8
atrial fibrillation
8
pulmonary vein
8
vein isolation
8
low-voltage areas
8
high-resolution substrate
8
substrate map
8
map recurrence
8
patients underwent
8
substrate ablation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!