Purpose: The purpose of this study was to determine whether the Scheimpflug tomographically normal fellow eyes of keratoconus patients are also classified as normal using an ectasia screening algorithm based on anterior segment optical coherence tomography (AS-OCT).

Methods: This monocentric cross-sectional study included 22 very asymmetric ectasia patients with tomographically significant keratoconus in 1 eye and normal Scheimpflug tomography in the fellow eye. Twenty-two eyes of 22 healthy subjects served as a control group. We performed corneal tomography using Pentacam AXL (Oculus, Wetzlar, Germany) and used Belin/Ambrósio Enhanced Ectasia total deviation index as well as Belin ABCD keratoconus classification to identify Scheimpflug tomographically normal eyes. We also performed AS-OCT using Anterion (Heidelberg Engineering, Heidelberg, Germany) and analyzed for the presence of ectasia using the Screening Corneal Objective Risk of Ectasia (SCORE) algorithm, with positive values indicating ectasia suspect tomography.

Results: The SCORE value was positive in 9.1% (n = 2) of the healthy eyes, in 45.5% (n = 10) of the Scheimpflug tomographically normal eyes of keratoconus patients and in all eyes (n = 22) with tomographically significant keratoconus. The Scheimpflug tomographically normal eyes of keratoconus patients had higher SCORE values compared with healthy controls ( P < 0.001). The median (interquartile range) SCORE value was -1.7 (1.3) in healthy controls, -0.5 (2.2) in Scheimpflug tomographically normal eyes of keratoconus patients, and 11.1 (11.0) in tomographically significant keratoconus eyes.

Conclusions: The Scheimpflug tomographically normal fellow eyes of keratoconus patients had higher AS-OCT-based SCORE values than healthy controls, with positive SCORE values found in 46% of the eyes, indicating early tomographic ectatic changes.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0000000000003518DOI Listing

Publication Analysis

Top Keywords

scheimpflug tomographically
28
tomographically normal
28
eyes keratoconus
20
keratoconus patients
20
normal eyes
16
fellow eyes
12
tomographically keratoconus
12
score values
12
healthy controls
12
eyes
11

Similar Publications

Purpose: The distinction between pellucid-like keratoconus (PLK) and pellucid marginal corneal degeneration (PMD) based on tomographic examinations is difficult. In this study, corneal tomographic and biomechanical parameters, after classifying PMD and PLK using swept-source optical coherence tomography, were analyzed.

Methods: Diagnoses of PLK and PMD were made using SS-OCT imaging, two groups were formed: PLK (n = 30) and PMD (n = 10).

View Article and Find Full Text PDF

Predicting corneal decompensation in Fuchs endothelial corneal dystrophy with Scheimpflug tomography and clinical parameters.

Indian J Ophthalmol

January 2025

Department of Ophthalmology, Université Paris Cité, Cochin Hospital, Assistance Publique-Hôpitaux de Paris, Paris, France.

Purpose: This study aims to evaluate the efficacy of various tomographic indices, both established and novel, in predicting endothelial decompensation leading to either spontaneous corneal transplantation or transplantation following cataract surgery in patients with Fuchs endothelial corneal dystrophy (FECD).

Methods: In this cross-sectional, retrospective study, we reviewed the files of 93 eyes from 54 FECD patients undergoing regular follow-up. We recorded clinical metrics such as morning visual disturbance (MVD) and corrected distance visual acuity.

View Article and Find Full Text PDF

: To determine the impact of corneal and biometry parameters on the normative root mean square (RMS) values of corneal aberrations measured at a 6 mm diameter. : The RMS values for corneal aberrations (anterior, posterior, and total) were measured along with corneal parameters using Scheimpflug tomography on 770 normal subjects. The biometric parameters were measured with an optical biometer.

View Article and Find Full Text PDF

Assessing Corneal Tomographic Changes in Fuchs Endothelial Corneal Dystrophy Over 1 year: Scheimpflug Versus Anterior Segment Optical Coherence Tomography.

Cornea

December 2024

Ophthalmology Biology, Engineering and Imaging Laboratory, Federative Institute of Research in Sciences and Health Engineering, Faculty of Medicine, Jean Monnet University, Saint-Etienne, France.

Purpose: The objective of this study was to compare the capacity of anterior segment optical coherence tomography (AS-OCT) and Scheimpflug camera in detecting tomographic changes over 1 year in a cohort of patients with Fuchs endothelial corneal dystrophy.

Methods: We conducted a single-center prospective study which consisted of 2 identical visits spaced 1 year apart. At each visit, tomographic analyses were performed using Scheimpflug imaging (Pentacam HR, Oculus) and swept source AS-OCT (Casia SS-1000 Tomey).

View Article and Find Full Text PDF

Purpose: To compare the parameters and indices of a novel swept-source optical coherence tomography device (SS-OCT, ANTERION) with those of a rotating Scheimpflug camera (RSC)-based tomograph (Pentacam) in normal and keratoconic (KC) eyes.

Methods: This prospective, monocentric, cross-sectional study included individuals with unoperated normal and KC eyes, selecting one eye per subject. Ectasia-specific parameters analysed with the SS-OCT were difference in mean keratometry (K) in the inferior and superior meridians, maximum keratometry value (K), elevation of the posterior surface at the thinnest point, screening corneal objective risk of ectasia (SCORE) and thinnest point thickness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?