Background: Acute hypoxemic respiratory failure is among the more commonly occurring complications in postoperative patients. Supplemental oxygen and addressing the primary etiology form the basis of its treatment.

Materials And Methods: We conducted an open-labeled randomized control trial with 90 adult patients and compared three oxygen delivery vehicles (ODV), i.e., noninvasive ventilation (NIV), high-flow nasal cannula (HFNC), and venturi mask (VM) in postoperative hypoxemic patients. The primary outcome variable was a change in the P/F ratio after 2 hours of use of ODV.

Results: It was observed that the change in P/F ratio after 2 hours was similar in all three ODV groups ( = 0.274). The mean values of the post-ODV P/F ratio were comparable with the pre-ODV P/F ratio in all three modalities. The P/F ratio after HFNC was 358.08 ± 117.95; after NIV was 357.60 ± 220.67; and after VM was 355.47 ± 101.90 ( = 0.997).

Conclusion: Among HFNC, NIV, and VM, none of the devices proved superior to the other for use in postoperative hypoxemia.

How To Cite This Article: Mishra S, Kothari N, Sharma A, Goyal S, Rathod D, Meshram T, . Comparison of Oxygen Delivery Devices in Postoperative Patients with Hypoxemia: An Open-labeled Randomized Controlled Study. Indian J Crit Care Med 2024;28(3):294-298.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10926037PMC
http://dx.doi.org/10.5005/jp-journals-10071-24659DOI Listing

Publication Analysis

Top Keywords

p/f ratio
20
oxygen delivery
12
postoperative patients
12
open-labeled randomized
12
comparison oxygen
8
delivery devices
8
devices postoperative
8
patients hypoxemia
8
hypoxemia open-labeled
8
randomized controlled
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!