Intraoperative Angle Measurement of Anatomical Structures: A Systematic Review.

Sensors (Basel)

IDMEC, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001 Lisboa, Portugal.

Published: March 2024

Ensuring precise angle measurement during surgical correction of orientation-related deformities is crucial for optimal postoperative outcomes, yet there is a lack of an ideal commercial solution. Current measurement sensors and instrumentation have limitations that make their use context-specific, demanding a methodical evaluation of the field. A systematic review was carried out in March 2023. Studies reporting technologies and validation methods for intraoperative angular measurement of anatomical structures were analyzed. A total of 32 studies were included, 17 focused on image-based technologies (6 fluoroscopy, 4 camera-based tracking, and 7 CT-based), while 15 explored non-image-based technologies (6 manual instruments and 9 inertial sensor-based instruments). Image-based technologies offer better accuracy and 3D capabilities but pose challenges like additional equipment, increased radiation exposure, time, and cost. Non-image-based technologies are cost-effective but may be influenced by the surgeon's perception and require careful calibration. Nevertheless, the choice of the proper technology should take into consideration the influence of the expected error in the surgery, surgery type, and radiation dose limit. This comprehensive review serves as a valuable guide for surgeons seeking precise angle measurements intraoperatively. It not only explores the performance and application of existing technologies but also aids in the future development of innovative solutions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10934548PMC
http://dx.doi.org/10.3390/s24051613DOI Listing

Publication Analysis

Top Keywords

angle measurement
8
measurement anatomical
8
anatomical structures
8
systematic review
8
precise angle
8
image-based technologies
8
non-image-based technologies
8
technologies
6
intraoperative angle
4
measurement
4

Similar Publications

Electronic confinement induced quantum dot behavior in magic-angle twisted bilayer graphene.

Nanoscale

January 2025

Transport at Nanoscale Interfaces Laboratory, Empa, Swiss Federal Laboratories for Materials Science and Technology, 8600 Dübendorf, Switzerland.

Magic-angle twisted bilayer graphene (TBLG) has emerged as a versatile platform to explore correlated electron phases driven primarily by low-energy flat bands in moiré superlattices. While techniques for controlling the twist angle between graphene layers have spurred rapid experimental progress, understanding the effects of doping inhomogeneity on electronic transport in correlated electron systems remains challenging. In this work, we investigate the interplay of confinement and doping inhomogeneity on the electrical transport properties of TBLG by leveraging device dimensions and twist angles.

View Article and Find Full Text PDF

Background: Soft tissue specifications and facial values ​​vary depending on the underlying skeletal structures. To achieve the ideal treatment result and patient satisfaction, one must know the attractive soft tissue specifications compatible with each type of malocclusion. This study aims to analyze the facial measurements that contribute to perceived facial attractiveness in patients with vertical growth patterns and skeletal class I malocclusion, focusing on gender-specific differences.

View Article and Find Full Text PDF

Background: Limited-angle (LA) dual-energy (DE) cone-beam CT (CBCT) is considered as a potential solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, its clinical implementations are hindered by the challenging image reconstruction from LA projections. While optimization-based and deep learning-based methods have been proposed for image reconstruction, their utilization is limited by the requirement for X-ray spectra measurement or paired datasets for model training.

View Article and Find Full Text PDF

Morphologic study of patent ductus arteriosus based on computed tomography data in 25 dogs.

Front Vet Sci

December 2024

Department of Veterinary Clinical Science, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul, Republic of Korea.

Introduction: The objective of this study is to analyze the morphology and measurement dimensions of patent ductus arteriosus (PDA) based on computed tomography images.

Methods: The present study retrospectively evaluated computed tomography angiography data from 25 client-owned dogs diagnosed with PDA. PDA was reconstructed based on the central axis and the minimum diameter, ampulla diameter, angle, ampulla cross-section area, and length values were measured at specific measurement sites.

View Article and Find Full Text PDF

Introduction: Anemia is a severe public health problem in India, affecting more than 50% of individuals across most age groups. The Anemia Mukt Bharat (AMB) program, with a target of a three-percentage point reduction in anemia prevalence per year, developed a monitoring mechanism based on a set of 18 indicators and six key performance indicators (KPIs) derived from routine reporting in the Health Management Information System (HMIS). The study's objective was to assess the status of anemia control measures in the district of Faridabad, Haryana, India, using AMB HMIS indicators from April 2018 to March 2019.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!