A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Exploring the Possibility of Photoplethysmography-Based Human Activity Recognition Using Convolutional Neural Networks. | LitMetric

Exploring the Possibility of Photoplethysmography-Based Human Activity Recognition Using Convolutional Neural Networks.

Sensors (Basel)

Department of Artificial Intelligence Convergence, Hallym University, Chuncheon 24252, Republic of Korea.

Published: March 2024

Various sensing modalities, including external and internal sensors, have been employed in research on human activity recognition (HAR). Among these, internal sensors, particularly wearable technologies, hold significant promise due to their lightweight nature and simplicity. Recently, HAR techniques leveraging wearable biometric signals, such as electrocardiography (ECG) and photoplethysmography (PPG), have been proposed using publicly available datasets. However, to facilitate broader practical applications, a more extensive analysis based on larger databases with cross-subject validation is required. In pursuit of this objective, we initially gathered PPG signals from 40 participants engaged in five common daily activities. Subsequently, we evaluated the feasibility of classifying these activities using deep learning architecture. The model's performance was assessed in terms of accuracy, precision, recall, and F-1 measure via cross-subject cross-validation (CV). The proposed method successfully distinguished the five activities considered, with an average test accuracy of 95.14%. Furthermore, we recommend an optimal window size based on a comprehensive evaluation of performance relative to the input signal length. These findings confirm the potential for practical HAR applications based on PPG and indicate its prospective extension to various domains, such as healthcare or fitness applications, by concurrently analyzing behavioral and health data through a single biometric signal.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10933912PMC
http://dx.doi.org/10.3390/s24051610DOI Listing

Publication Analysis

Top Keywords

human activity
8
activity recognition
8
internal sensors
8
exploring possibility
4
possibility photoplethysmography-based
4
photoplethysmography-based human
4
recognition convolutional
4
convolutional neural
4
neural networks
4
networks sensing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!