A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Coronary intravascular lithotripsy for severe coronary artery calcification: The Disrupt CAD I-IV trials. | LitMetric

Coronary intravascular lithotripsy for severe coronary artery calcification: The Disrupt CAD I-IV trials.

Cardiovasc Revasc Med

Innovative Medical Solutions, Beverly Hills, CA, United States of America. Electronic address:

Published: August 2024

Coronary artery calcification (CAC) severity is associated with increased vessel inflammation, atherosclerosis, stent failure, and risk of percutaneous coronary intervention-related complications. Current modalities for CAC modification include atherectomy techniques (rotational, orbital, and laser) and balloon modification (cutting and scoring). However, these methods are limited by their risk of slow flow/no reflow, coronary dissection, perforation, and myocardial infarction. Intravascular lithotripsy (IVL) emits high-energy sonic waves that induce calcium fractures within a target lesion to improve vessel compliance for stent placement. Low rates of major cardiac adverse events (MACE) and high rates of procedural and angiographic success were observed with IVL in the Disrupt CAD I-IV trials. Optical coherence tomography sub-studies identified calcium fracture as the likely etiology of improved vessel compliance and increased luminal diameter post-IVL. Rates of MACE, procedural, and angiographic success were consistent across the Disrupt CAD trials, suggesting IVL is less operator-dependent compared to other calcium-modifying techniques. Coronary IVL offers interventional cardiologists a safe and effective method of severe CAC modification, while providing reproducible outcomes.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.carrev.2024.03.001DOI Listing

Publication Analysis

Top Keywords

disrupt cad
12
intravascular lithotripsy
8
coronary artery
8
artery calcification
8
cad i-iv
8
i-iv trials
8
cac modification
8
vessel compliance
8
procedural angiographic
8
angiographic success
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!