Background: Cryoballoon ablation is currently the gold standard technique for single-shot pulmonary vein isolation (PVI). Pulsed field ablation (PFA) has recently emerged as an interesting nonthermal alternative energy for PVI. The purpose of our study was to evaluate the safety and long-term efficacy of PVI using the pentaspline PFA catheter in comparison to cryoballoon ablation.
Methods And Results: Between January 2021 and December 2022, we included all consecutive patients of our center in whom a first PVI-only procedure was performed using PFA or cryoballoon. The choice of the energy was based on patients' preference between general anesthesia (PFA) and local anesthesia (cryoballoon). The primary end point was freedom from documented atrial arrhythmia recurrence after a 3-month blanking period. A total of 301 patients (paroxysmal atrial fibrillation in 220 patients) underwent a first PVI procedure performed using PFA (n=151) or cryoballoon (n=150). Complete short-term PVI was obtained in 144 of 150 patients (96%) in the cryoballoon group and in all patients of the PFA group (=0.01). Procedure duration was significantly longer in the cryoballoon group. Transient and persistent phrenic nerve injuries were observed in the cryoballoon group only (13/150 and 2/150, respectively). One-year freedom from atrial arrhythmia was significantly higher in the PFA group compared with the cryoballoon group (87.9% versus 77.7%; adjusted hazard ratio, 0.53 [95% CI, 0.30-0.96]; =0.037).
Conclusions: This prospective, comparative, real-life study suggested that PFA could overcome safety limitations of cryoballoon with optimal effectiveness. Randomized controlled studies are required to further investigate the potential superiority of PFA over cryoballoon.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11010030 | PMC |
http://dx.doi.org/10.1161/JAHA.123.033146 | DOI Listing |
Pacing Clin Electrophysiol
December 2024
Department of Cardiology, International University of Health and Welfare Hospital, Tochigi, Japan.
Background: Cryoballoon ablation has been widely performed in patients with paroxysmal atrial fibrillation (AF). In some challenging pulmonary veins (PVs), the procedure requires additional touch-up applications against the residual conduction gaps. It implies that there could exist difficult sites to cover with standard cryoballoon applications (CBAs), resulting in resistant conduction gaps (RCGs).
View Article and Find Full Text PDFJ Cardiovasc Electrophysiol
December 2024
Department of Cardiovascular Medicine, Institute of Science Tokyo, Tokyo, Japan.
Background: Cryoballoon ablation is less operator-dependent than radiofrequency ablation. Recently, size-adjustable cryoballoons (SA-CBs) have become available. We sought to analyze the individual baseline operator experience's impact on procedural results.
View Article and Find Full Text PDFJ Interv Card Electrophysiol
December 2024
Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
Background: A phrenic nerve injury (PNI) during cryoballoon (CB) pulmonary vein isolation (PVI) continues to represent a limitation of this technique. The objective of this study was to develop a novel technique with the aim of reducing the incidence of PNI.
Methods: We performed a retrospective analysis of data from two hospitals in patients with symptomatic, drug-resistant atrial fibrillation (AF) over 7 years to evaluate the incidence and clinical characteristics of PNI during cryoballoon PVI.
J Cardiothorac Surg
December 2024
The Shengli Clinical Medical College, Fujian Medical University, Fuzhou, 350001, Fujian Province, P.R. China.
Background: We attempted to establish correlations between intraoperative variables such as time-to-isolation (TTI) and temperature (T) at the 30-second mark, and the sustained efficacy of pulmonary vein isolation.
Methods: One hundred patients underwent repeat procedures subsequent to their index ablation. Five time intervals were delineated based on TTI metrics of 30, 35, 40, 45, and 60 s during the initial procedure.
Circ Arrhythm Electrophysiol
December 2024
Yonsei University Health System (D.K., H.T.Y., T.-H.K., J.-S.U., B.J., M.-H.L., H.-N.P.).
Background: Pulmonary vein isolation (PVI) alone is less effective in patients with persistent atrial fibrillation (AF) compared with those with paroxysmal AF. We investigate whether additional linear ablation from the superior vena cava to the right atrial septum and cavotricuspid isthmus ablation improves the rhythm outcome of patients with persistent AF undergoing cryoballoon PVI (Cryo-PVI).