Cone beam computed tomography (CBCT) is known to suffer from strong scatter and cone beam artifacts. The purpose of this study is to develop and characterize a rapidly scanning carbon nanotube (CNT) field emission x-ray source array to enable a multisource CBCT (ms-CBCT) image acquisition scheme which has been demonstrated to overcome these limitations. A CNT x-ray source array with eight evenly spaced focal spots was designed and fabricated for a medium field of view ms-CBCT for maxillofacial imaging. An external multisource collimator was used to confine the radiation from each focal spot to a narrow cone angle. For ms-CBCT imaging, the array was placed in the axial direction and rapidly scanned while rotating continuously around the object with a flat panel detector. The x-ray beam profile, temporal and spatial resolutions, energy and dose rate were characterized and evaluated for maxillofacial imaging. The CNT x-ray source array achieved a consistent focal spot size of 1.10 ± 0.04 mm × 0.84 ± 0.03 mm and individual beam cone angle of 2.4°±0.08 after collimation. The x-ray beams were rapidly switched with a rising and damping times of 0.21 ms and 0.19 ms, respectively. Under the designed operating condition of 110 kVp and 15 mA, a dose rate of 8245Gy swas obtained at the detector surface with the inherent Al filtration and 2312Gy swith an additional 0.3 mm Cu filter. There was negligible change of the x-ray dose rate over many operating cycles. A ms-CBCT scan of an adult head phantom was completed in 14.4 s total exposure time for the imaging dose in the range of that of a clinical CBCT scanner. A spatially distributed CNT x-ray source array was designed and fabricated. It has enabled a new multisource CBCT to overcome some of the main inherent limitations of the conventional CBCT.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6560/ad3323 | DOI Listing |
Medicine (Baltimore)
January 2025
Department of Medical Imaging, Jincheng People's Hospital, Shanxi, China.
Rationale: Thrombus is the most common occupying lesion in the cardiac chambers, it is often distinguished from cardiac neoplastic occupations. Among them, the most common is cardiac myxoma, whose imaging manifestations are often confused with thrombus. However, the 2 types of lesions have different therapeutic strategies and are both potentially high-risk sources of embolism, so early differentiation between intracardiac thrombus and cardiac tumor is essential.
View Article and Find Full Text PDFClin Nucl Med
January 2025
From the Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), NMPA Key Laboratory for Research and Evaluation of Radiopharmaceuticals (National Medical Products Administration), Department of Nuclear Medicine; Peking University Cancer Hospital and Institute, Beijing, China.
Purpose: The aim of this study was to compare Al18F-NOTA-HER2-BCH and 18F-FDG for detecting nodal metastases in patients with HER2-positive breast cancer on PET/CT.
Patients And Methods: In this retrospective study, 62 participants with HER2-positive breast cancer underwent both Al18F-NOTA-HER2-BCH and 18F-FDG PET/CT. Participants were pathologically confirmed as HER2-positive (IHC 3+ or IHC 2+ with gene amplification on FISH).
PLOS Glob Public Health
January 2025
Médecins Sans Frontières, International, Geneva, Switzerland.
Ultraportable (UP) X-ray devices are ideal to use in community-based settings, particularly for chest X-ray (CXR) screening of tuberculosis (TB). Unfortunately, there is insufficient guidance on the radiation safety of these devices. This study aims to determine the radiation dose by UP X-ray devices to both the public and radiographers compared to international dose limits.
View Article and Find Full Text PDFPLoS One
January 2025
Ocean Georesources Research Department, Korea Institute of Ocean Science and Technology, Busan, Republic of Korea.
Banded iron formations (BIFs), significant iron ore deposits formed approximately 2.3 billion years ago under low-oxygen conditions, have recently gained attention as potential geological sources for evaluating hydrogen (H₂) production. BIFs are characterized by high concentrations of iron oxide (20 to 40 wt.
View Article and Find Full Text PDFNeurol Int
January 2025
Neuroradiology Unit, Azienda Unità Sanitaria Locale-IRCCS di Reggio Emilia, Viale Risorgimento 80, 42123 Reggio Emilia, Italy.
Cerebral venous thrombosis (CVT) is a rare and potentially critical cerebrovascular disease involving intracranial dural sinuses and veins. The diagnosis is a stepwise pathway starting from clinical suspicion and employing several neuroradiological techniques, mainly Computed Tomography (CT)-based and Magnetic Resonance Imaging (MRI)-based modalities. The neuroradiological findings, both in the diagnostic phase and in the follow-up phase, may provide some results at risk for misdiagnosis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!