Feasibility of proton dosimetry overriding planning CT with daily CBCT elaborated through generative artificial intelligence tools.

Comput Assist Surg (Abingdon)

Department of Electronics, Information and Bioengineering, Politecnico di Milano, Milan, Italy.

Published: December 2024

Radiotherapy commonly utilizes cone beam computed tomography (CBCT) for patient positioning and treatment monitoring. CBCT is deemed to be secure for patients, making it suitable for the delivery of fractional doses. However, limitations such as a narrow field of view, beam hardening, scattered radiation artifacts, and variability in pixel intensity hinder the direct use of raw CBCT for dose recalculation during treatment. To address this issue, reliable correction techniques are necessary to remove artifacts and remap pixel intensity into Hounsfield Units (HU) values. This study proposes a deep-learning framework for calibrating CBCT images acquired with narrow field of view (FOV) systems and demonstrates its potential use in proton treatment planning updates. Cycle-consistent generative adversarial networks (cGAN) processes raw CBCT to reduce scatter and remap HU. Monte Carlo simulation is used to generate CBCT scans, enabling the possibility to focus solely on the algorithm's ability to reduce artifacts and cupping effects without considering intra-patient longitudinal variability and producing a fair comparison between planning CT (pCT) and calibrated CBCT dosimetry. To showcase the viability of the approach using real-world data, experiments were also conducted using real CBCT. Tests were performed on a publicly available dataset of 40 patients who received ablative radiation therapy for pancreatic cancer. The simulated CBCT calibration led to a difference in proton dosimetry of less than 2%, compared to the planning CT. The potential toxicity effect on the organs at risk decreased from about 50% (uncalibrated) up the 2% (calibrated). The gamma pass rate at 3%/2 mm produced an improvement of about 37% in replicating the prescribed dose before and after calibration (53.78% vs 90.26%). Real data also confirmed this with slightly inferior performances for the same criteria (65.36% vs 87.20%). These results may confirm that generative artificial intelligence brings the use of narrow FOV CBCT scans incrementally closer to clinical translation in proton therapy planning updates.

Download full-text PDF

Source
http://dx.doi.org/10.1080/24699322.2024.2327981DOI Listing

Publication Analysis

Top Keywords

cbct
11
proton dosimetry
8
generative artificial
8
artificial intelligence
8
narrow field
8
field view
8
pixel intensity
8
raw cbct
8
planning updates
8
cbct scans
8

Similar Publications

Background: This study aims to evaluate the impact of different thresholds and voxel sizes on the accuracy of Cone-beam computed tomography (CBCT) tooth reconstruction and to assess the accuracy of fused CBCT and intraoral scanning (IOS) tooth models using curvature continuity algorithms under varying thresholds and voxel conditions.

Methods: Thirty-two isolated teeth were digitized using IOS and CBCT at two voxel sizes and five threshold settings. Crown-root fusion was performed using a curvature continuity algorithm.

View Article and Find Full Text PDF

Investigating paranasal sinuses developmental disorders and septum deviation angle effects on olfactory fossa depth using cone-beam computed tomography.

Dent Res J (Isfahan)

November 2024

Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Islamic Azad University, Isfahan (Khorasgan) Branch, Isfahan, Iran.

Background: The ethmoid roof separates the ethmoid cells from the anterior cranial fossa. From the medial side, the roof of the ethmoid is connected to the lateral lamella of the ethmoid plate, which is the thinnest bone at the base of the skull and is most vulnerable to damage during endoscopic surgeries. The purpose of this study is to investigate the height of the lateral lamella in patients with hypoplasia/aplasia of the paranasal sinuses and deviation of the nasal septum using reconstructed multiplanar images by cone-beam computed tomography (CBCT).

View Article and Find Full Text PDF

Background: Dens invaginatus is a developmental abnormality originating from tooth development, including coronal invaginatus and radicular invaginatus. The reported incidence varies greatly due to diagnostic techniques, classification criteria and race. The incidence of dens invaginatus in China was not clear, and the impact of dens invaginatus on periodontal support tissue were rarely reported.

View Article and Find Full Text PDF

Digital planning and decision making for severe congenital oligodontia with Angle class-III malocclusion - Case series.

J Craniomaxillofac Surg

December 2024

Department of Oral and Maxillofacial Surgery, Rambam Health Care Campus, Haifa, Israel; Bruce Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel; Department of Oral and Maxillofacial rehabilitation, Rambam Health Care Campus, Haifa, Israel.

As maxillofacial surgery becomes increasingly digitized and the transformative impact of pre-surgical scanning and computer simulation is recognized, this clinical paper presents an algorithm for the selection of interventions in severe congenital oligodontia with Angle class-III malocclusion (OCIII) utilizing such technologies. A complex, multifactorial condition with varying degrees of craniofacial involvement, OCIII is associated with edentulous facial appearance, mandibular prognathism and deep underbite, as well as malocclusion. Our methodology involves the integration of CBCT imaging, intra- and extra- oral scanning, and 3D planning with the assessment of bone volume, number of missing teeth, skeletal discrepancies, and patient compliance in the selection of suitable treatments.

View Article and Find Full Text PDF

Intrafraction Patient Positional Uncertainty in Lung Stereotactic Ablative Radiotherapy with Abdominal Compression.

Pract Radiat Oncol

December 2024

Department of Radiation Oncology, Willis Knighton Cancer Center, 2600 Kings Highway, Shreveport, Louisiana, USA 71103 &, Department of Clinical Research, University of Jamestown, Fargo, ND, USA. Electronic address:

Purpose: Motion management presents a significant challenge in thoracic stereotactic ablative radiotherapy (SABR). Currently, a 5.0 mm standard planning target volume (PTV) margin is widely used to ensure adequate dose to the tumor.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!